Chore-Tronics Model 16 & 8 Control
Initial Setup
11
MT1554A
VAR FAN 1 & 2
1, 2 ,3, and 4 are the only values that can be edited. If the variables
are to function independently of each other, the “On” for variable 2
has to be set at 2.5°F above the “On” for variable 1.
If the “on” for both variables are the same, then they will function
identically.
Types of Timers
There are two types of timers.
1.
The first type is only used for COOL outputs. It modulates (turns on and off) a
COOL output above the COOL output’s “on temperature”.
2.
The second type of timer is used on EXH FAN, STIR FAN, TUN FAN (Model
16) and VAR FAN 1 outputs. It modulates an output below these output’s “on
temperature”.
Key
Description
1
Minimum Speed 1
2
Minimum Speed 2
3
*Variable Fan 1 – on
4
*Variable Fan 2 – on
5
2.5° Fahrenheit – minimum allowed
6
.5° Fahrenheit – fixed
7
Variable Fan #1 – Full Speed
8
Variable Fan #2 – Full Speed
9
Increase Temperature
*See Outputs-Temperatures BUTTON 3
MT1554-04 8/98