NEXGEN60 InstallationRev1
Page
25
of
42
04/11/2022
Viewing or Changing Set-points
Press MENU then SERVICE then SETPOINT to access the set-point screen. From this
screen the SALT SETPOINT, PH SETPOINT, ACID FEED TIME, and MINIMUM
SALINITY can be adjusted. The factory default is 7000 for salt, 7.4 for pH, and 60
seconds for feed time.
Adjusting pH Feed Times
Press MENU then SERVICE then SETPOINT to access the set-point screen. From this
screen the PH FEED TIME can be adjusted. The factory default is 60 seconds.
Accessing the Recorded Event Log
Press MENU then SERVICE then RECORD to access the event log screen. The event
log will store every system event that has occurred by date and order.