background image

 

 

 

July 2018 

443580508481 

Signify North America Corporation

 

200 Franklin Square Drive

 

Somerset, NJ  08873, USA

 

Phone:  855-486-2216

 

www.chloride-lighting.com

 

 

Signify Canada Ltd./Signify Canada Ltée. 
281 Hillmount Road,

 

Markham, ON, Canada  L6C 2S3

 

Phone:  800-668-9008

 

 

 

HZ SERIES 

EMERGENCY TWO-HEAD LED EXIT  

 

 

IMPORTANT 

SAFEGUARDS 

 

When using electrical equipment, basic safety 
precautions should always be followed, including the 
following: 

 

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS 

 

All servicing should be performed by qualified personnel 
only. 
 
Do not mount near any heat producing equipment. 
Equipment should be mounted in locations and at heights 
where it will not be readily subjected to tampering by 
unauthorized personnel. 
 
The use of accessory equipment not recommended by the 
manufacturer may cause an unsafe condition. 
Do not use this equipment for other than intended use. 
 
In Class I Division 2 locations, do not replace any 
non-metallic hardware with metal hardware. Contact 
authorized agent for factory replacement parts. 
In Class I Division 2 areas, install equipment in 
accordance with appropriate NEC articles plus any 
other applicable codes. 
 
To avoid static discharge, do not attach any ungrounded 
metal hardware to the enclosure. 
Do not store or place flammable materials near lamp. 
Install only grounded wiring systems to supply this 
equipment 

 
CAUTION

 – 

ensure lamp heads are positioned  

so they are aimed below horizontal

 

 

CLASS I DIV 2 

HAZARDOUS LOCATION 

GROUPS A, B, C, AND D 

ZONE 2 GROUPS IIC, IIB AND IIA 

CLASS II DIV 2 GROUPS F AND G 

AND CLASS III DIV 1 AND 2 

 

INSTALLATION AND OPERATING 

INSTRUCTIONS 

 
                                 
  
 

 
 
 
 
 

                                                                                                                                      

Do not use this equipment outdoors

 

CAUTION

: Halogen cycle lamp(s) are used in this 

equipment. To avoid shattering: Do not operate 
lamp in excess of rated voltage, protect lamp 
against abrasion and scratches and against liquids 
when lamp is operating, dispose of lamp with care. 
Halogen cycle lamps operate at high temperatures. 

Do not store or place flammable materials near lamp. 

 
CAUTION

: “To avoid electrical overload, total 

connected lamp load (factory and field installed) 
should not exceed output rating”. 
Free installation area of hazardous atmospheres 
before wiring equipment or servicing, this reduces 
the risk of accidental explosion due to inadvertent 
battery shorting during installation. 
 

SAVE THESE 

INSTRUCTIONS 

 

WARNING  –  Shut off AC power to branch 
circuits to which units will be connected. All 
wiring should be per NEC wiring methods for 
Hazardous locations. 

 

To maintain warranty, equipment with 
batteries must be installed or placed on charge 
within prescribed period after shipment. 
 
 

Содержание HZ Series

Страница 1: ...d metal hardware to the enclosure Do not store or place flammable materials near lamp Install only grounded wiring systems to supply this equipment CAUTION ensure lamp heads are positioned so they are aimed below horizontal CLASS I DIV 2 HAZARDOUS LOCATION GROUPS A B C AND D ZONE 2 GROUPS IIC IIB AND IIA CLASS II DIV 2 GROUPS F AND G AND CLASS III DIV 1 AND 2 INSTALLATION AND OPERATING INSTRUCTION...

Страница 2: ...r is used a Connect WHITE wire to 24VDC Positive and 24VDC Negative b Use wire nuts for connection not supplied 7 Connect Battery connectors to the panel See Figures 4 and 6 8 Adjust head s as follows See Figure 3 a Rotation Loosen head nut and rotate head to desired position Retighten head nut An antirotation screw has been provided to ensure proper rotation b Angle Loosen thumb screw passing thr...

Страница 3: ...hone 855 486 2216 www chloride lighting com Signify Canada Ltd Signify Canada Ltée 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 INSTRUCTIONS OPERATION 1 Energize AC power to exit Unit will initiate normal power up sequence See page 4 Figure 3 Battery Connectors Figure 4 Figure 5 Figure 6 ...

Страница 4: ...ating condition Rapid Flash product performing an automatic or manually initiated diagnostic test Red LED indicator Single Flash battery fault Two Flashes lamp failure light bar failure EXIT signs Three Flashes charger fault Four Flashes transfer fault If more than one fault condition is present simultaneously the red LED will flash the indication pattern for each fault independently then repeat t...

Страница 5: ...hone 855 486 2216 www chloride lighting com Signify Canada Ltd Signify Canada Ltée 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 IR Remote Control optional is a hand held device that allows remote activation of diagnostic testing and silencing of the optional buzzer during fault conditions ...

Страница 6: ... VOLTAGE DROP 5 CM L X 22 USING THE ABOVE FORMULA AND HAVING CALCULATED THE CIRCULAR MILLS REQUIRED TO CARRY THE SPECIFIED LOAD AT A PREDETERMINED AND ALLOWABLE VOLTAGE DROP THE FOLLOWING CHART WILL IDENTIFY THE NECESSARY WIRE GAUGE FROM THE CORRESPONDING CIRCULAR MILL SIZE LISTED WIRE GAUGE AMPERE CAPACITY OHMS PER 1000 ft CIRCULAR MILL SIZE 12 20 1 586 6 530 10 25 9972 10 380 8 35 6271 16 510 6 ...

Страница 7: ... North America Corporation 200 Franklin Square Drive Somerset NJ 08873 USA Phone 855 486 2216 www chloride lighting com Signify Canada Ltd Signify Canada Ltée 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 Figure 7 ...

Страница 8: ...one 855 486 2216 www chloride lighting com Signify Canada Ltd Signify Canada Ltée 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 Top Assembly Drawing For Reference only Heads Batteries Chassis assembly Lens Figure 8 Batteries Control Board Membrane switch Chassis assembly back view Figure 9 ...

Отзывы: