background image

 

 

 

 

 

 

 

 

 

 

 

 

 

CYT-133SC 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Document Version 1.0 

Web Version 1.2 2011-03-07 

Firmware Version 1.02.00,Mar 8 2011 

Содержание CYT-133SC

Страница 1: ...CYT 133SC User Manual Document Version 1 0 Web Version 1 2 2011 03 07 Firmware Version 1 02 00 Mar 8 2011 ...

Страница 2: ...4 I O State Setup 24 5 Alert Event E Mail 25 6 DDNS Setup 26 1 TZ0 26 2 Dyndns 27 Management 28 1 Device Administration Setting 28 2 System Status Monitor 29 3 I O Status 30 1 Non Extend I O Mode 30 2 Extend I O Mode 31 4 Backup Restore Configuration 32 5 Firmware Upgrade 33 6 PING 34 Appendix A CYT 133SC DIO Command Protocol Appendix A 1 Appendix B Remote reset command Appendix B 1 Appendix C CGI...

Страница 3: ...distance RS 485 Data Data GND 1200M for the longest distance I O Control 3 Input short 3 Output Relay Mode Maximum Voltage DC30V 1A Power Input Choose one PWR1 DC9 24V 500MA MAX 2 pin Separate terminal PWR2 DC9 24V 500MA MAX DC power to DC socket Operating Temperature 0 55 Operating Humidity 5 95 RH Storage Temperature 20 85 Surge Protection Serial port 15KV ESD Electromagnetic protection Ethernet...

Страница 4: ... 2 End point ...

Страница 5: ...dial up connection and remote host Support Dynamic DNS this enable CYT 133SC connect with dynamic IP by fixed Domain Name enable hosts situated in different location to get access to CYT 133SC through internet Auto detecting 10 100 M Ethernet Enable users to conduct data access or management on CYT 133SC through various operation system of IE Netscape browser Allows users to back up and store file...

Страница 6: ...with power supplied If the default IP address 192 168 168 125 is occupied by else device then it is a must to shut down that device first till the setting is over and then allocate new IP address to CYT 133SC How to search CYT 133SC 1 After installation of CYT 133SC and network cable is completed use CYT 133SC s IP Search to search all CYT 100SC in a certain LAN or download IP Search tool from CHI...

Страница 7: ... Address Select particular CYT 133SC then its related information will appear below the window as shown 4 The showed information of CYT 133SC can be revised directly in the window the part can be modified IP Address Subnet Mask Gateway After modification completed MAC Address can not modify click Alter then it will display the modified information as shown ...

Страница 8: ...C has two methods 1 Open IP Search select and double click particular CTY 133SC then to enter its webpage 2 While the internet explorer opened input CYT 133SC IP address to enter its webpage Remark WINDOWS XP Step 1 Click WINDOWS XP my computer Open Control Pan on the left side please turn to traditional overview and select network link Step 2 Click LAN then select content the link configuration w...

Страница 9: ... select open and search for click Alter Interface Card on the upper left side Step 2 Click LAN link select content then the LAN settings will be shown click Internet Protocol TCP IPv4 click and input same setting as CYT 133SC as below figure ...

Страница 10: ...T 133SC connection input command ping 192 168 168 125 as shown below If no response received it explains the link has troubles either the connection is not proper or the PC s IP address can not match with CYT 133SC s IP address Set the PC s IP address with CYT 133SC s IP address with same segment if the PC uses fixed IP address the address must be ranged in 192 168 168 1 192 168 168 65 or 192 168 ...

Страница 11: ...splay a message window for User name and Password the default for user name and Password is admin admin as shown below 4 While the user name and password entered a Web setting interface of CTY 133SC will be showed enter it will then display a One Page Quick Setup page ...

Страница 12: ...is 168 95 1 1 Serial Port Mode Baud Rate 1 Set serial port baud rate the parameters can be selected 1200 2400 4800 9600 19200 38400 57600 115200 230400 and Others 2 After selecting Others fill custom baud rate into the user defined 3 Default setting is 19200 Serial Server Mode Connection Mode There are 5 modes to set into connection mode such as Real Com TCP SERVER TCP CLIENT UDP Extend I O no dat...

Страница 13: ...200 230400 and Others 2 After selecting Others fill custom baud rate into the user defined 3 Default setting is 19200 Serial Server Mode Connection Mode There are 5 modes to set into connection mode such as Real Com TCP SERVER TCP CLIENT UDP Extend I O no data conversion Connection Port Number Set CYT 133SC connection port number default setting is 50000 Remote Host IP Address 1 Set the remote hos...

Страница 14: ... Fixed IP Address After selecting ENABLE fill in fixed IP Default setting is DISABLE optional Serial Port Mode Baud Rate 1 Set serial port baud rate the parameters can be set 1200 2400 4800 9600 19200 38400 57600 115200 230400及 Others 2 After selecting Others fill custom baud rate into the user defined 3 Default setting is 19200 Serial Server Mode Connection Mode There are 5 modes to set into conn...

Страница 15: ...onnect with monitoring side or the connection will be off automatically when remote idle Access Password Make sure the data secure user must set the code for management User must inset the correct password and process the further procedure after authority up to 31 characters Keep Alive Check Set Enable or Disable keep alive check function default setting is Disable While keep alive check enable th...

Страница 16: ...0 0 TCP Connection There are 2 modes to set TCP connection to server 1 Start Up This mode means when CYT 133SC enable it will build the TCP connection with SERVER immediately It will automatically build the TCP connection after disable and then re connect again 2 Any Character This mode means only when CYT 133SC receives data from RS232 422 485 it will build TCP connection with SERVER TCP connecti...

Страница 17: ...Remote Host IP Address Set remote host IP address or domain name default setting is 0 0 0 0 Local Listen Port Set the local listen port default setting is 50000 Heart Beat How many seconds to transmit a UDP heart beat to server can be selected It s helpful to know the connection with SERVER enabled Default setting is Disabled and the maximum setting is 65535 seconds ...

Страница 18: ...n It can expend I O by connect with BF 51 Structure PS BF 51 is the I O box with 3 sets of DI DO TID set by DIP switch and maximum can connect with BF 51 9 OUT 1 to 3 IN 1 to 3 IN 4 to 6 OUT 4 to 6 IN 7 to 9 OUT 7 to 9 IN 28 to 30 OUT 28 to 30 RS485 CTY 133SC Master BF51 TID 1 BF51 TID 2 BF51 TID 9 ...

Страница 19: ...Xoff Software flow control CTS RTS Hardware flow control Default setting is None Force Packet Transmit Time 10ms Force packet transmit time The minimum setting is 10ms of setting serial interval between data Default setting is 20ms Force Packet Transmit Length bytes Force packet transmit length The serial set length of data transmission range is from 1 1500bytes Default setting is 1000 Delimiter 1...

Страница 20: ...n make the linked connection of each I O For instance there are 2 devices to connect with IN1 IN2 and OUTPUT1 The trigger mode is IN1 IN2 trigger OUTPUT1 at the same time The OUTPUT1 configuration is IN1 and IN2 Through alarm output setting it can send alarm mail to user when OUTPUT 1 3 has been triggered When select AUTO mode command mode connection will be disabled ...

Страница 21: ...se conditions to set For instance When IN1 IN2 and IN3 enable at the same time meanwhile OUTPUT1 will be triggered The setting condition must be IN1 AND IN2 AND IN3 Alarm Generation Enable or disable alarm output function the default setting is Enable When OUTPUT2 has been triggered alarm mail will send to user automatically OUTPUT 3 Triggered Rule Set trigger OUTPUT 3 condition use IN1 3 AND and ...

Страница 22: ...ring side or the connection will be off automatically when remote idle Access Password Make sure the data secure user must set the code for management User must inset the correct password and process the further procedure after authority up to 31 characters Auto Report I O Status Automatically return I O status Disable No automatically return I O Status State Changed I O status will be returned au...

Страница 23: ... Host IP Address Default setting of remote host IP address is 0 0 0 0 Auto Report I O Status Automatically return I O status Disable No automatically return I O Status State Changed I O status will be returned automatically when INPUT changes Periodically Set I O status return automatically every few seconds Through I O status will be returned thru Serial and ETH ...

Страница 24: ...g of remote host IP address is 0 0 0 0 Local Listen Port Default setting of local I O port is 50001 Auto Report I O Status Automatically return I O status Disable No automatically return I O Status State Changed I O status will be returned automatically when INPUT changes Periodically Set I O status return automatically every few seconds Through I O status will be returned thru Serial and ETH ...

Страница 25: ...r IP Default setting of remote peer IP address is 0 0 0 0 Structure 1 IN1 IN2 IN3 OUT1 OUT2 OUT3 Extend I O Mode RS485 IN1 IN2 IN3 IN28 IN29 IN30 OUT1 OUT2 OUT3 OUT28 OUT29 OUT30 CYT 133SC LAN WAN LAN WAN CYT 133SC CYT 133SC BF51 BF51 RS485 CYT 133SC BF51 BF51 Structure 2 ...

Страница 26: ...n up to 23 characters STATUS Set Enable or Disable INPUT2 detection INPUT 3 INPUT 3 status can set OPEN or SHORT default setting is OPEN Can set device name in Device Description for identification up to 23 characters STATUS Set Enable or Disable INPUT3 detection OUTPUT 1 OUTPUT 1 setting when INPUT signal changes can set OUTPUT into OPEN or SHORT default setting is SHORT Can set device name in De...

Страница 27: ...etting is Disable Domain Name optional Domain name setting up to 59 characters default setting is blank Non required SMTP Mail Server SMTP server setting take msa hinet net for instance the setting is up to 47 characters E mail Alerts To Receiver mail setting up to 47 characters Return Address Sender mail setting up to 47 characters ...

Страница 28: ... key Fill in the password key for DDNS up to 31 characters Device DNS Name Fill in the device DNS name for example hostname tzo com Registry IP Address Display the registry IP address when DDNS is enabled It will show the registry IP address Status Display DNS Serve status when DDNS server does not enable it will show DDNS function is disabled ...

Страница 29: ... the password for DDNS up to 31 characters Device DNS Name Fill in the device DNS name for example hostname dyndns org Registry IP Address Display the registry IP address when DDNS is enabled It will show the registry IP address Status Display DNS Serve status when DDNS server does not enable it will show DDNS function is disabled ...

Страница 30: ...name default setting is CHIYU Device Location Fill in the device location default setting is blank Administrator Password User Name Fill in the user name Password Change Change the password for security reasons please fill in a new password to replace the default management Password Confirm Confirm the new password Block Ping Request Select unblock or block ping request function default setting is...

Страница 31: ...dress Display CYT 133SC address default setting is 192 168 168 125 Subnet mask Display CYT 133SC Subnet mask default setting is 255 255 255 0 Default Gateway Display CYT 133SC Default Gateway default setting is 192 168 168 254 Primary DNS Display CYT 133SC Primary DNS address default setting is 168 95 1 1 STATUS Display CYT 133SC internet status Force Packet Time Length Display Force Packet Time L...

Страница 32: ... INPUT 3 CYT 133SC INPUT 3 status display OUTPUT 1 CYT 133SCOUTPUT 1 status display Click SHORT 1 or OPEN 1 manual control OUTPUT 1 OUTPUT 2 CYT 133SCOUTPUT 2 status display Click SHORT 2 or OPEN 2 manual control OUTPUT 2 OUTPUT 3 CYT 133SCOUTPUT 3 status display Click SHORT 3 or OPEN 3 manual control OUTPUT 3 Refresh Click Refresh to get the I O updated status ...

Страница 33: ... status display Click SHORT 2 or OPEN 2 manual control OUTPUT 2 OUTPUT 3 CYT 133SCOUTPUT 3 status display Click SHORT 3 or OPEN 3 manual control OUTPUT 3 Refresh Click Refresh to get the I O updated status BF 51 status BF51 1 9 Status BF 51 status display 1 9 indicates TID of BF 51 Status BF 51 status display Online or Offline INPUT BF 51 INPUT status display X means disconnect OUTPUT BF 51 OUTPUT...

Страница 34: ...uction Function Description Backup After execution can save the present system settings as a backup file and save it in hardware the sub name of the saved file is cfg Restore Browse and select saved file cfg execute Restore to restore system settings ...

Страница 35: ...file to upgrade Browse and select firmware execute Upgrade to upgrade firmware Has to assure the possibility of power supply during the process of upgrading or severe damage will be caused What if upgrade different firmware to different products and it will also cause severe damage ...

Страница 36: ...T 133SC IP address Destination IP Address Input IP address of Remote Host Packet Number Set up the number of PING package ranged 1 4 the default 4 Ping Size Set up the size of PING package the utmost setting 1460 bytes Ping Result Display Sent Request data Display Receive Reply data ...

Страница 37: ... 133SC returns by Return packet You can get command status to know the result after sending command packet and from Data1 and Data2 to know current I O state Note Start Flag 0xF0F0 End Flag 0xF0F0 Command Status the definition of command code is as following 0x0002 ACK of Read Digital I O state 0x0004 ACK of Trigger Digital I O 0x0006 ACK of E mail Alarm Trigger 0x0010 Report current Digital I O s...

Страница 38: ...ta 31 IN 1 IN 2 IN 29 IN 30 reserved reserved IN 1 state of IN1 0 for SHORT 1 for OPEN 2 for Deactivated IN 2 state of IN2 0 for SHORT 1 for OPEN 2 for Deactivated IN 30 state of IN30 0 for SHORT 1 for OPEN 2 for Deactivated Data2 Data 0 Data 1 Data 28 Data 29 Data 30 Data 31 OUT 1 OUT 2 OUT 29 OUT 30 reserved reserved OUT 1 state of OUT1 0 for SHORT 1 for OPEN 2 for Deactivated OUT 2 state of OUT...

Страница 39: ...OUT30 0 for SHORT 1 for OPEN Data2 for Latch time in second Data 0 Data 1 Data 28 Data 29 Data 30 Data 31 LT 1 LT 2 LT 29 LT 30 reserved reserved Return Successful Packet Length Bytes 2 2 32 32 2 1 0xF0F0 0x0004 Xxx don t care Xxx don t care 0xF0F0 CRC 3 E mail Alarm Trigger Length Bytes 2 2 32 32 2 1 0xF0F0 0x0005 Alarm Message Description 0xF0F0 CRC Alarm Message Description string of alarm mess...

Страница 40: ...PEN 2 for Deactivated Data2 Data 0 Data 1 Data 2 Data 3 Data 30 Data 31 OUT 1 OUT 2 OUT 3 reserved reserved reserved OUT 1 state of OUT1 0 for SHORT 1 for OPEN OUT 2 state of OUT2 0 for SHORT 1 for OPEN OUT 3 state of OUT3 0 for SHORT 1 for OPEN 5 Keep Alive Only useful when CYT 133SC s I O mode is acting as TCP Client CYT 133SC Host Length Bytes 2 2 64 2 1 0xF0F0 0x0007 RESV 0xF0F0 CRC 0x0007 Kee...

Страница 41: ...admin b CHIYU proprietary command UDP connection port 5050 Byte SNG 16 CMD 4 SNG 16 bytes signature data should be CHIYU Reboot CMD case sensitive CMD 4 bytes 0x00 00 00 20 Return packet Byte SNG 16 ACK 4 SNG 16 bytes signature data should be CHIYU Reboot CMD case sensitive ACK 4 bytes 0x00 00 00 21 ...

Страница 42: ...ay No 1 all the time http 192 168 3 125 set_relay php no 1 time 0 admin admin Energize Relay No 2 and latch 10 seconds http 192 168 3 125 set_relay php no 2 time 10 admin admin Clear Output Relay command For example Clear Relay No 1 http 192 168 3 125 clear_relay php no 1 admin admin Clear Relay No 2 http 192 168 3 125 clear_relay php no 2 admin admin Username Password ...