15
Data PORT 2
(1) TCP Server
Function Description
Local Listen Port Number:
If the device is using the TCP/IP protocol to drive the data transfer via remote instructions, the
Serial Server Mode must be set to TCP SERVER and the LISTEN PORT NUMBER setting and
monitoring side must be the same value. The default value is 50001.
Close Connection When Remote Idle:
Set the idle disconnection time, the default value is 30 seconds, the range is 0 ~ 32768.
When you want to maintain the connection between BF-1010 and the monitoring terminal at any
time, you must set the value to 0, otherwise when there is no data on the line and the
transmission exceeds the set time, the connection will be automatically disconnected.
Max Connection:
Set the maximum number of TCP connections, up to 3 TCP connections, the default value is 3.
Access Password:
To ensure the security of assets, the user can set a password to enter and control. When the
assets are transferred, the correct password must be entered to obtain permission before entering.
It can enter up to 31 characters.
Keep Alive Check:
When connected, a ping packet is sent to the Gateway Router to ensure the connection every 30
seconds.