BCD-430WP Service Manual
33
How to change the compressor and how to disconnect and weld the refrigeration
system pipeline.
(Note: If the refrigerant R600a is used,operations should be made in the environment where
there is good ventilation and free from open fire.)
1. Cut off power supply, take foods out of
the refrigerator, and secure all doors with
adhesive tapes to prevent the door from
falling off when the refrigerator gets tilted.
2.Tilt the refrigerator slowly forward,
leaning itagainst the wall or the object that
is strong enough, and leave sufficient space
for operation. For safety reasons, you need
someone to help support the refrigerator
to prevent it from toppling down.
3.Cut off the compressor pipeline
-❶Truncate the process tube
-❷Truncate the low-pressure air return
pipe
-❸Truncate the high-pressure exhaust
pipe.
4. Remove screws:
- 2 outside screws;
- 1 inside screw;