background image

    BCD-430WP Service Manual 

15 

off;Ifthe  LED  lamp  turns  on/off  as  the  door  is  opened/closed,  the  proximity 

switch  and  magnet  under  test  are  qualified;  otherwise,  the  proximity  or 

magnet  is  unqualified.  Replace  the  unqualified  proximity  switch  or  magnet, 

close the door, and then observe whether the door open alarm is eliminated 

or not. For the compartment with no LED lamp, replace the proximity switch 

or  magnet  directly,  and  then  close  the  door,  observing  whether  the  door 

open alarm is eliminated. 

e.

 

If  the  alarm  continues,  cut  off  power  supply,  change  the  display  panel,  and 

wait for 3 minutes after power-on, observing whether the alarm is eliminated 

or not. 

3.

 

Other fault phenomena and maintenance methods 

(1)

 

The  refrigeratordoes  not  work.  (The  whole  machineis  not  working,  with  the 

compressor  not  started,  the  display  panel  not  illuminatedand  the  LED  lamp  OFF 

when the door is opened.) 

a.

 

Check  whether  the  refrigerator  plug  is  properly  plugged  in;  whether  the 

socket is electrified; and whether the socket voltage is normal. 

b.

 

Cut off power supply, remove the electrical box cover, observing whether the 

terminals are properly connected, reinsert the terminals, and then power on 

the system to observe whether the refrigerator can work normally. 

c.

 

Cut  off  power  supply,  change  the  main  board,  insert  the  terminal  well,  and 

power on the system to observe whether the refrigerator can work normally. 

(2)

 

The compressorcannot start. (Other devices are working normally) 

The  compressor  shutdown  duringthe  normal  operation  of  the  refrigerator  does 

not  belong  to  this  type  of  failure.  Be  sure  to  wait  for  at  least  5  minutes  before 

starting  the  compressor  again  in  the  case  of  compressor  shutdown.  During  the 

following  maintenance  operations,  if  a  power  failure  occurs,  please  wait  for  5 

minutes,  and  then  power  on  the  system  to  observe  the  compressor  working,  or 

wait  for  5  minutes  after  the  system  is  powered  on  to  observe  whether  the 

compressor can work normally or not. 

a.

 

Cut  off  power  supply,  remove  the  electrical  box  cover,  check  whether  the 

terminals  are  properly  connected,  insert  them  again,  and  then  power  on  the 

system to observe whether the compressor can start normally. 

b.

 

If it still cannot start, cut off power supply, remove the compressor cover, check 

whether the compressor protector is properly plugged in, reconnect it, and then 

power on the system, observing whether the compressor can start normally or 

not. 

c.

 

If it still cannot start, cut off power supply, replace the control board, and power 

on  the  system  after  inserting  well  the  terminal,  observing  whether  the 

Содержание BCD-430WP

Страница 1: ...BCD 430WP Service Manual 1 Refrigerator Service Manual Applicable to Model FCD418NE3 BCD 430WP C1647...

Страница 2: ...Product features 3 II Outer appearance and structure 4 III Main technical parameters IV Operating instructions 5 V Display rules 8 VI Cooling system 9 VII Control system 9 VIII Maintenance guide 11 I...

Страница 3: ...chine engineering design this hidden handle refrigeratorhas an elegant and novel appearance Multi airflow The stereo multiple air outlets are adopted by the refrigerator which guarantees uniformity of...

Страница 4: ...ual 4 II Outer appearance and structure Note Due to technological innovation the product descriptions in this manual may not be completely consistent with your refrigerator Details are in accordance w...

Страница 5: ...ion program is enabled temperature setting becomes invalid 2 Every time when settings are finished with no flickering any more if the Temp Zonekey is pressed again the Fridge icon starts flickering fi...

Страница 6: ...t press this key to select the function and then press the OK key the function will exit 2 Function program rules Refer to the operation of Keys and press the keys to perform the corresponding functio...

Страница 7: ...rature is set at 14 which is subjected to no change 4 When the Vacation function is exited the fridge temperature is restored to its original value that is set before the Vacation function is enabled...

Страница 8: ...ent corresponding compartment is displayed with the 2 digit and icons flickering Over temperature alarm When energized if the freezer sensor temperature is higher than 10 its corresponding icon and te...

Страница 9: ...ncluding the control system diagram main control board circuit layout diagram each component control 1 Schematic diagram of the control system Components output capillary tube filter condenser anti co...

Страница 10: ...Anti condensation heater 230V 50Hz 8W LECO 12VDC 1W Buzzer LEDdisplay Fridge lamp 12V MAX2 5W Freezer fan 12VDC 3W Freezer defrosting heater 230V 50Hz 200W 2 Diagram of the control board the board in...

Страница 11: ...ezer door is opened running of the fan motor gets suspended for 5 minutes 5 Power cut memory a The temperature setting of each compartment can be memorized b Such functional state as Smart Fast Freeze...

Страница 12: ...be displayed instead 2 In case the number of sensor faults or compartment sensor faults is more than two the number will be displayed 2 Fault troubleshooting How to detect the fault is presented here...

Страница 13: ...ther there is alarm displayed on the panel 3 Freezer evaporator fault the freezer zone icon gets flickering with E1 displayed a Cut off power supply remove the electrical box cover check whether the t...

Страница 14: ...3 minutes the display panel lights up and the buzzer issues the alarm sound at the frequency of 1Hz indicating the door is not closed tightly a Open all the doors and close them again checking whether...

Страница 15: ...tem to observe whether the refrigerator can work normally c Cut off power supply change the main board insert the terminal well and power on the system to observe whether the refrigerator can work nor...

Страница 16: ...opened b Open the door and hold the door lamp switch by hand to check if the LED lampturns on and off as the door lamp switch is connected and disconnected If not refer to the Door Open Alarm section...

Страница 17: ...ut off power supply remove the electrical box cover check whether the terminals on the main board are properly connected insert them well again and then power on the system when the door is opened wai...

Страница 18: ...check whether the terminals on the main board are properly connected b After the power is cut off remove the freezer air duct assembly checking whether the defrosting heater terminal is properly conne...

Страница 19: ...How to check the fuse 1 Dismantle the freezer air duct assembly by referring to the disassembly method of freezer air duct assembly unplug the fuse terminal set the multimeter as illustrated below and...

Страница 20: ...s unchanged the fuse is judged to be blown out and needs to be replaced 4 Special programs Maintenance program by holding down the combination keys of Function and OK 1 When you press the Temp Zone ke...

Страница 21: ...e running of the maintenance program the compressor keeps rotating at 3000rpm 4 After the operating state is set the refrigerator will run according to the maintenance program 5 During the running of...

Страница 22: ...remove the two screws with the screwdriver b Remove the round lampshade fixed by three jaws on top of the fridge air hood and remove the one screw with a screwdriver c After removing the three screws...

Страница 23: ...perature sensor a Remove the air duct assembly by referring to the instructions for dismantling the fridge air duct assembly and then remove the air hood b Tear off the sponge in the air hood and remo...

Страница 24: ...lectric pen or flat screwdriver and then replace it directly How to dismantle the fridge top LED lamp a Pry up the lamp shade using an electric pen or flat screwdriver The lamp shade is fixed byclampi...

Страница 25: ...lder and then unplug the terminal on the back side How to dismantle the flip beam a Remove the two screws in the middle of the flip beam with a screwdriver b After removing the screws pull the flipbea...

Страница 26: ...and pull the display panel out b Unplug the connector terminal on the top of the display panel then the display panel assembly can be taken off c The display panel is fixed by two screws and four claw...

Страница 27: ...iver b Push out the freezer partition boardin the arrow direction as illustrated and take out the partition board from top to bottom How to dismantle the freezer air duct assembly a Use a screwdriver...

Страница 28: ...the freezer air duct assembly from the bottom up c After pulling out the air duct assembly unplug the molded case connector on the back and then remove the air duct assembly How to dismantle the free...

Страница 29: ...ture How to dismantle the heater a Remove the freezer air duct assembly by reference to the instructions for dismantling the freezer air duct assembly b Unplug the heater connector terminal screw off...

Страница 30: ...How to remove the fuse a Refer to the instructions for dismantling the freezer air duct assembly and heater and remove the freezer air duct assembly and the evaporator assembly b Unplug the fuse term...

Страница 31: ...plug the two connector terminals c Remove the hinge cover and screw off the three bolts that secure the hinge then the hinge can be dismantled d Use a flathead screwdriver to pry out the door lamp swi...

Страница 32: ...the main board and unplug all the connector terminals on the main board then the main board can be disassembled How to dismantle the compressor compartment a Use a screwdriver to remove the nine screw...

Страница 33: ...doors with adhesive tapes to prevent the door from falling off when the refrigerator gets tilted 2 Tilt the refrigerator slowly forward leaning itagainst the wall or the object that is strong enough...

Страница 34: ...ve cover 7 Disassemble the starter and protector Unplug the starter and protector in turn you can use a screwdriver to slowly pry them off 8 Loosen the fixing screws of the compressor on the bottom pl...

Страница 35: ...th a pipe cutter and cut off the capillary tube using the capillary pliers 11 Replace the compressor and weld the pipes Weld the process tube Weld the low pressure air return pipe T Weld the high pres...

Страница 36: ...36 13 Conduct vacuum pumping with the vacuum degree reaching below 10Pa 14 Charge the system with refrigerant 15 Use thelocking pliers to clamp the middle of the process tube and then weld the proces...

Отзывы: