![Chippmann Omega-PhiCS-8 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/chippmann/omega-phics-8-series/omega-phics-8-series_owners-manual_2602578016.webp)
CS-8 Series Omega-Phi Rev1.04, Oct. 2015
-14-
7.
Range MID
25-gauge-Trimmer
P5
– calibration of the standard A (440 Hz)
8.
Range high
25-gauge-Trimmer
P4
– calibration of the upper frequency
(7040 Hz, upper row)
9.
ZERO
25-gauge-Trimmer
P12
– calibration to 0 Hz at Bias = Zero & exp.
frequency = 50 kHz
10.
korr high
25-gauge-Trimmer
P1
– calibration of gain error of the e-
generator at 20 kHz
11.
PVCA off
12-gauge-Trimmer
P6
– Offset-calibration of the phase
modulation-VCA's
12.
1 V/ OCT
25-gauge-Trimmer
P3
– calibration of the scale at jack "36" to 1
Volt/octave
13.
FVCA off
12-gauge-Trimmer
P7
– Offset-calibration of the frequency
modulation-VCA
14.
16 Pin power supply-box header
7.3 Initial operation
The power connector’s (8) pin-out in top view (refer to fig. 2) is assigned as
follows:
Bottom to top, left to right. Thus pin 1 is located at bottom left, pin 2 above pin
1 etc. Pin 15 is at bottom right, pin 16 at top right.
Pin 1, 2 = -12 V (labeled with a triangle)
Pin 3-8 = GND (regarding ground, 0 V), located outward on all jacks
Pin 9, 10 = +12 V
Pin 11-16 = not connected
To hook up power to the module, connect one of the IDC-connector of the
included flat ribbon cable to the box header (refer to fig. 2). Observe guide key
for the polarity of the connector in order to avoid pin reversal. The red tag of
the cable is to match the triangle-label.
8. MODULE DESCRIPTION
8.1. Layout and functions