CS-8 Series COOK Rev1.3, Feb. 2019
-12-
and the parameters
A/R Time
,
Threshold/Ratio
and
Response
th e VCA is
controlled by the RMS-converter, leading finally to dynamic compression.
Input
This section includes the
jack 6 (Input)
and the
controller 1 (Input)
. The input
signal applied at
jack 6
is routed AC-coupled to
Cont. 1
where it get an
attenuation between 0 (-
∞
db, full CCW) and 1 (0 db, full CW). To obtain a
signal gain of 1 (
Cont. 5
at full CCW) at the signal output
Out
Cont. 1
has to be
set to full CW.
Ratio/Threshold/Make-up Gain
This section includes the
controller 5
(
Th/Rt
)
and th e
jack 7
(
Thres/Ratio
)
. A
picture paints a th ousand words. Figure 4 sh ows a family of curves for
corresponding input-to-output levels at rising
Thres/Ratio
values.
Fig. 4 Threshold / Ratio