1- SAFETY REGULATION
1.1- SAFETY LABELING AND WARNING SIGNS
The words DANGER and WARNING are used to identify the levels of
seriousness of certain hazards. It is important that you understand their
meaning. You will notice these words in the manual as follows:
DANGER
Immediate hazards that WILL result in death, serious bodily injury
and/or property damage
WARNING
Hazards or unsafe practices that CAN result in death, bodily injury
and/or property damage.
NOTE
: is used to highlight suggestions which will result in enhanced
installation, reliability or operation.
1.2- IMPORTANT INFORMATION
DANGER
Non-observance of the safety regulations outlined in this manual will
potentially lead to consequences resulting in death, serious bodily injury
and/or property damage.
It is the homeowner’s responsibility to engage a qualified technician for the
installation and subsequent servicing of this furnace;
Before calling for service, be sure to have the information page of your
manual close by in order to be able to provide the contractor with the
required information, such as the model and serial numbers of the furnace.
WARNING
Installations and repairs performed by unqualified persons can result in
hazards to them and to others. Installations must conform to local codes
or, in the absence of same, to codes of the country having jurisdiction.
The information contained in this manual is intended for use by a
qualified technician, familiar with safety procedures and who is
equipped with the proper tools and test instruments
1.3- DETECTION SYSTEMS
It is recommended that carbon monoxide detectors be installed wherever
oil or gas fired heaters are used. Carbon monoxide can cause bodily harm
or death. For this reason, agency approved carbon monoxide detectors
should be installed in your residence and properly maintained to warn of
dangerously high carbon monoxide levels.
There are several sources of possible smoke and flames in a residence.
Smoke and flames can cause bodily harm or death. For this reason, agency
approved smoke detectors should be installed in your residence and
properly maintained, to warn early on, of a potentially dangerous fire. Also,
the house should be equipped with approved and properly maintained fire
extinguishers.
Your unit is equipped with safety devices that can prevent it from
functioning when anomalies are detected such as a blocked venting
system.
WARNING
CARBON
MONOXIDE
POISONING/COMPONENT
DAMAGE
HAZARD
Failure to follow this warning could result in personal injury or death and
unit component damage.
Corrosive or contaminated air may cause failure of parts containing flue
gas, which could leak into the living space. Air for combustion must not
be contaminated by halogen compounds, which include fluoride,
chloride, bromide, and iodide. These elements can corrode heat
exchangers and shorten furnace life. Air contaminants are found in
aerosol sprays, detergents, bleaches, cleaning solvents, salts, air
fresheners, and other household products. Do not install furnace in a
corrosive or contaminated atmosphere. Make sure all combustion and
circulating air requirements are met, in addition to all local codes and
ordinances.
WARNING
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK,
AND
CARBON
MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage. Improper installation,
adjustment, alteration, service, maintenance, or use can cause carbon
monoxide poisoning, explosion, fire, electrical shock, or other conditions
which may cause personal injury or property damage. Consult a
qualified service agency, local gas supplier, or your distributor or branch
for information or assistance. The qualified service agency must use
only factory authorized and listed kits or accessories when modifying
this product.
WARNING
FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING
HAZARD
Failure to follow this warning could result in personal injury, death, or
property damage.
Never operate a furnace without a filter or filtration device installed.
Never operate a furnace with filter or filtration device access doors
removed.
Untrained personnel can perform basic maintenance functions such as
cleaning and replacing air filters. All other operations must be performed
by trained service personnel. When working on heating equipment,
observe precautions in literature, on tags, and on labels attached to or
shipped with furnace and other safety precautions that may apply.
These instructions cover minimum requirements and conform to existing
national standards and safety codes. In some instances, these instructions
exceed certain local codes and ordinances, especially those that may not
have kept up with changing residential construction practices. We require
these instructions as a minimum for a safe installation.
Follow all safety codes. Wear safety glasses, protective clothing, and work
gloves. Have a fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in literature and
attached to the unit.
Содержание c105-1-d
Страница 20: ...20 Figure 16 Wiring diagram One stage PSC ...
Страница 21: ...21 Figure 17 Two Stage PSC Furnace Control ...
Страница 22: ...22 Figure 18 Two Stage ECM Furnace Control ...
Страница 26: ...26 Figure 21 Direct venting Figure 22 Multi venting ...
Страница 37: ...37 Figure 25 Part list 1 Stage PSC ...
Страница 38: ...38 Figure 26 Part list 1 Stage PSC continued ...
Страница 41: ...41 Figure 27 Part list 2 Stage PSC ...
Страница 42: ...42 Figure 28 Part list 2 stage PCS continued ...
Страница 45: ...45 Figure 29 Part list X13 ...
Страница 46: ...46 Figure 30 Part list X13 continued ...
Страница 49: ...49 Figure 31 Part list 2 Stage ECM ...
Страница 50: ...50 Figure 32 Part list 2 Stage ECM continued ...