Please store this instruction
manual in a designated place for
future reference.
INST.No.TPS-02
TP-S
Instruction Manual
CHINO
Страница 1: ...Please store this instruction manual in a designated place for future reference INST No TPS 02 TP S Instruction Manual CHINO ...
Страница 2: ...ontents of packing If something is missing please contact to your nearest distributor The batteries are not loaded in this product with shipment Referring to Loading replacing of battery P 2 load 2 pieces of AA UM 3 alkaline battery and use this product The supplied batteries are for operation check We are no guarantee of their life The eneloop batteries are recommended to use this product Easy Th...
Страница 3: ...ccurate However should any errors be found or important information be omitted please inform your nearest distributor The eneloop is the registered trademark of SANYO Electric Co Ltd of Panasonic Group The company names and brand names used in this manual are the trademarks or registered trademarks of respective companies About exemption from responsibility Unless otherwise specified in the guaran...
Страница 4: ...scattering of the sensor etc Do not drop it or have strong shocks on this product Avoid the use of this product in the following places A place where ambient temperature varies widely A place where humidity is high A place where rain water is splashed A place where there are dusts like sand or dirt A place where it is subjected to exposed in scorching heat or direct sunlight A place where it s sub...
Страница 5: ...rap and to brandish a product It causes an accident and an injury the damage of household effects the trouble For cleaning this product except the lens use neutral detergent and wipe it off lightly by rubbing with the cloth squeezed firmly Do not use chemicals or bleaches including benzene thinner and alcohol For cleaning the lens wipe off dust and dirt with a blower Do not wash the lens with wate...
Страница 6: ... to operate keys 1 POWER key 5 2 Measure key 5 Contents displayed 6 For accurate measurement 8 Setting of emissivity 8 Setting Emissivity Reference 9 Setting of color palette 10 Switching the temperature unit 11 Connection of external power source 11 Specifications 12 Precautions For maintaining of measurement accuracy 13 Troubleshooting 14 External dimensions 14 ...
Страница 7: ...1 Names and functions Micro USB port Shutter Batter cover releasing switch Batter cover Batter cover releasing switch Display MEASURE key POWER key ...
Страница 8: ... using the eneloop for this product Cautions For replacing the batteries be careful that water drops etc do not get in the inside of this product For opening the battery cover make sure the battery cover is not facing down If not the batteries may jump out of this product Refer to the figure shown below Don t mix and use a new dry cell an old dry cell and the dry cell by which a kind is different ...
Страница 9: ...ions Passing of strap Replace or take of the strap following the procedure shown below Push the battery cover releasing switches at both sides Pull the battery cover downward and take of the battery cover from this product Movable range of shutter About 90 Do not move the shutter forcedly it may cause breakage of the shutter Move the shutter referring to the movable range shown in the right figure...
Страница 10: ...ion Return the battery cover to this product Close the battery cover by pressing until it clicks Cautions Do not take of the battery cover forcedly it may cause breakage of this product Do not pull the strap rapidly The strap may come off Do not lift the product by grasping the battery cover There are cases where the battery cover is removed from the product and falls Set the cord of the strap to ...
Страница 11: ...re will be updated With the MEASURE key being pressed the measurement will be continuously executed By releasing the MEASURE key the measured value will be held Furthermore in the hold condition by pressing the MEASURE key to target a new measuring object the temperature of the new object will be measured and its temperature will be held by releasing the MEASURE key Cautions Do not press with a sh...
Страница 12: ...n the holding condition a frame border will be appeared on the measured value indication portion Battery power indicator Measurement point Fixed at center Measured value indication Measuring condition With the MEASURE key being pressed the mode becomes the measuring condition On the measuring condition a frame border on the measured value indication portion will be disappeared and the measured tem...
Страница 13: ...ries referring to the table shown below Display Battery power Replace the batteries Connected to an external power source The changing speed of the battery power indication will largely affected by the kind of batteries being used and ambient temperature Fully charged Fully discharged Battery power indicator Blinking ...
Страница 14: ...Nos 6 7 and 8 in the figure shown above of the 8 digit slide switch placed on the bottom edge portion of the battery housing The factory default emissivity is 0 95 5 kinds of the emissivity can be set from 0 80 to 1 00 with 0 05 increments Set the emissivity referring to the setting mode of the slide switch shown on the battery cover or the table sown below No 6 No 7 No 8 Emissivity OFF OFF OFF ε ...
Страница 15: ... on the objects material surface conditions measuring temperatures and so on The table below shows emissivity of some objects Please note that these values are just for reference Emissivity of Objects Material Emissivity Water Ice 0 98 Soil 0 92 0 96 Concrete wet 0 96 0 98 Concrete dry 0 91 0 95 Ceramics 0 85 0 95 Stone Asbestos 0 92 Plastics 0 90 0 95 Rubber black 0 95 Wood 0 98 Paper 0 92 Cloth ...
Страница 16: ...Change the color palette by referring to the settings of the slide switch shown in the table below No 2 No 3 Color palette Drawing No OFF OFF Iron ON OFF Rainbow OFF ON Gradation ON ON Gray Caution Do not change any digits other than the digits specified If not it may cause abnormal operation When operating the 8 digit slide switch please use a precision screwdriver If not the 8 digit slide switch...
Страница 17: ...en operating the 8 digit slide switch please use a precision screwdriver If not the 8 digit slide switch might be damaged Connection of external power source Through Power can be supplied to this product By connecting a battery pack to the micro USB port located on the side of this product power can be supplied When a battery pack is connected the indication of the battery power indicator Refer to...
Страница 18: ...nch color organic EL display Display size 28mm x 28mm Measurement indication function Spot temperature indication 1 point Fixed at center Function keys POWER key Turning power on off Press and hold to turn off MEASURE key Pressing the key starts measurement and releasing the key holds the measured value Working temperature range 0 C to 50 C Working humidity range 10 to 80 RH no dew condensation St...
Страница 19: ...for maintaining the measurement accuracy Vibration and shock Vibration and shock causes not only a damage to the thermal image sensor in a long term but in stability of the measurement Light path Select a measurement place where water drops dirt dust smoke steam or other foreign substances are not existed between the thermal image sensor and a measuring object Disturbances causing higher temperatu...
Страница 20: ...rature range of use for the batteries Manganese batteries are used Use the eneloop or alkaline batteries Image temperature value abnormally fluctuates Strong statistic electricity electromagnetic wave or high frequency may be present around the sensor Keep this product away from an equipment generating strong static electricity or electromagnetic wave Area of the measuring object is too small Conf...