![Chino IR-BAT Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/chino/ir-bat-series/ir-bat-series_instructions-manual_2602211002.webp)
INST No. INE-412-P7CE
For the purpose of using this thermometer safely, observe the following cautions for safety
during the operation, maintenance, and repair of this thermometer.
Take safety measures separately against wrong operation, troubles, and other circumstances
of this thermometer if necessary.
This instruction manual uses the following symbol marks for safe.
CAUTIONS FOR SAFETY
Item
Cautions
Power supply
Make sure that the voltage of the power source meets the rated power supply of
this thermometer before operation.
Prohibition of use in a
gaseous atmosphere
Never operate this thermometer at a place where a combustible gas, an
explosive gas or their vapors exist, otherwise a very dangerous accident
will occur. It is extremely dangerous to use this thermometer under such
environments.
Never touch the interior
To prevent from trouble, don't touch the inside of this thermometer by hand.
Caution on external
connections
For connection to external equipment, make sure to turn off the power supply
and also read instruction manual for the equipments.
Prohibition disassembling
and modification
Don't disassemble nor modify this thermometer. If you disassemble or
modify this thermometer, it will be dangerous to causing the trouble.
Cautions on maintenance
and check of the lens
When wiping out the dirt of the lens, don't use organics solvents except an
alcohol, water and the detergents absolutely.
If used, it will cause the trouble.
Type
Model
Measuring
range
Response
time (*)
Diameter/
Distance
Measuring
wavelength
G
en
er
a
l
General type
IR-BAT1A
0 to 300 ºC
100ms
Ø40/500mm
8 to 14
m
IR-BAT1B
0 to 600 ºC
Small diameter, short distance
IR-BAT2A
0 to 300 ºC
100ms
Ø5/80mm
Small diameter, long distance
IR-BATSA
0 to 300 ºC
100ms
Ø40/1000mm
IR-BATSB
0 to 600 ºC
Type
Model
Measuring
range
Response
time (*)
Measuring
diameter
Measuring
wavelength
H
ig
h
sp
ee
d
General type
IR-BAT1M
0 to 300 ºC
50ms
Ø40/500mm
8 to 14
m
IR-BAT1P
0 to 600 ºC
Small diameter, short distance IR-BAT2M
0 to 300 ºC
50ms
Ø5/80mm
Small diameter, long distance
IR-BATSM
0 to 300 ºC
50ms
Ø40/1000mm
IR-BATSP
0 to 600 ºC
Observe this caution item strictly for avoiding a danger, otherwise negligence of this
caution may cause an electric shock accident or other accidents resulting in
operator’s death or injuries.
Observe this caution item strictly, otherwise negligence of this caution may cause the
damage of this thermometer or measuring errors.
This mark is attached to each title covering
instructions
This mark shows the act of the prohibition.
W a r n i ng
C au t i on
!
Warnin g
FOR SAFE USE
1.Models and main specifications
(*Response time: 95
)