16
4.2 Setting Room Number
This process is operated at Outdoor Station.
(1) Set ISN code of each indoor unit according to the < 4-Port Distributor ISN Code
Chart > and < 6-Port Distributor ISN Code Chart >.
(2) Press
“ ##923132008 ”
continuously on Outdoor Station’s keyboard, then the
display shows “ _
001
”
(3) Press ISN code , then press
“ # ”
to confirm.
(4) The screen shows dead number
“FFFF”.
(If it shows other four numbers, this
outdoor station has already been encoded.)
(5) Change the room number, enter 4-digit number.
(e.g. Room 301 → entering “0301”.)
(6) Press
“ # ”
to confirm the room number. Then the screen shows the next ISN
code. Repeat the above steps to continue.
Press
“ * ”
to log out or it will log out in 10s automatically.
(7) Press
“ 8 ”
represents “Number Up” to jump over to find the specific room
number,when setting ISN code ; press
“9”
represents “Number Down”. (
“000”
is
the first ISN code of the Outdoor Station.)
4.3 Setting Building Number and Unit Number
※
This process is operated on the Network Cable Converter.
※
There are 4 buttons on the Network Cable Converter,
“ +1000 ” “ +100 ”
Содержание PST-VDA-R2