ChinaPST PST-VDA-R2 Скачать руководство пользователя страница 1

Apartment video door phone

1

Содержание PST-VDA-R2

Страница 1: ...Apartment video door phone 1...

Страница 2: ...Diagram 11 4 System Setting 12 4 1 Setting ISN Code 12 4 2 Setting Room Number 15 4 3 Setting Building Number and Unit Number 15 4 4 Setting of Gate Entry Station 17 4 5 Setting Network Cable Convert...

Страница 3: ...ne for villa single family house single apartment 1 Connect with CAT 5e UTP Unshielded Twisted Pair 2 CAT 5e transmit audio signal RS487 communication video signal 3 Access control function ID IC card...

Страница 4: ...nt 300mA Working 20mA Standby Wiring requirements Connection CAT5e Cat6 Cable normal network cable Power line RVV2 0 75 Lock line RVV2 0 75 2 The Instruction 2 1 Outdoor Station Figure 1 Card Reader I...

Страница 5: ...om Suitable for Multi apartment Suitable for Digital system Receive call from Guard Station and Indoor Unit One Outdoor Station is compatible to 1024 rooms at maximum CAT5e CAT6 network cable for conn...

Страница 6: ...When electrified if there is any unexpected situation happened please cut off power immediately until the fault is removed 4 If it is in abnormal status cut off power first And check it carefully Any...

Страница 7: ...the hole in wall or door is bigger 5mm than the box 2 Put the bottom box fixed in the hole of the door or wall 3 Connected with the network cable 4 Fix the outdoor station to the installation bottom b...

Страница 8: ...Press Answer call confirm it and press to unlock Door To unlock the door please press first then press C When the indoor unit is called it will stop ringing in 90 seconds without answering D When in s...

Страница 9: ...rectly to make the light s on Not ring after being called Check the speaker music chip and peripheral circuit Replace music chip The screen doesn t work Check the control module and circuit Correctly...

Страница 10: ...station Do not open the distributor without the presence of professionals 2 4 Power supply Model Power supply Power supply supplied power for outdoor station indoor unit distributor EML etc Input 220...

Страница 11: ...erformance and ensure years of trouble free use before operating it Figure 4 The wiring of Multi apartment system Non networking CAT5e Cable 8 core Power Lock Cable RVV 2 0 75mm Remark 1 Each power su...

Страница 12: ...partment System 12 Remark 1 Suitable for one building 2 If there are more than one building managed by management center please see Figure 9 Page 14 3 Please connect power supply to 220V Alternating C...

Страница 13: ...N button the light flashes 1 time which refers to ten digit 4 1 4 Press LOW button the light flashes 1 time which refers to single digit 4 1 5 After setting the code wait for 10s The power s light wil...

Страница 14: ...7 038 039 010 10 10 4 040 041 042 043 011 11 11 4 044 045 046 047 012 12 12 4 048 049 050 051 013 13 13 4 052 053 054 055 014 14 14 4 056 057 058 059 015 5 15 4 060 061 062 063 016 16 16 4 064 065 066...

Страница 15: ...8 056 057 058 059 060 061 008 8 8 8 064 065 066 067 068 069 009 9 9 8 072 073 074 075 076 077 010 10 10 8 080 081 082 083 084 085 011 11 11 8 088 089 090 091 092 093 012 12 12 8 096 097 098 099 100 1...

Страница 16: ...ion has already been encoded 5 Change the room number enter 4 digit number e g Room 301 entering 0301 6 Press to confirm the room number Then the screen shows the next ISN code Repeat the above steps...

Страница 17: ...n seconds after setting It will turn off 5 Pressing on button 1000 once represents 1000 pressing on 1000 button twice represents 2 000 Examples are as follows A NO 1 Unit 1 Building Press 1 button onc...

Страница 18: ...ep pressing the 1000 button for 3 seconds when the Network Cable Converter is electrified The light is on and release the button Examples are as follows NO 1111 Building A Press 1000 button once The L...

Страница 19: ...med status They work in 30 seconds after setting 3 Connection of Security Zones Security Zone NO 1 2 3 4 5 Color of Wire Red Blue Black Yellow White Security Zone NO 6 7 8 Ground Wire Color of Wire Gr...

Страница 20: ...will show OPEN If it is not it will show Err5 and exit setting 6 ID IC Card 6 1 Initialization Setting Set two administrator cards Turn card reader off put JUMP1 on position 12 turn card reader on the...

Страница 21: ...p Beep Exit 6 4 Unlock Time Set time gap of unlock by adjusting position of JMP2 Put JMP2 on place 1 2 The unlock time is 1s Put JMP2 on place 2 3 The unlock time is 5s 6 5 Delete All Cards You can de...

Страница 22: ...ards by themselves Press 13 CALL Green light is on Swipe cards continuously The process will not exit automatically Press CALL Red light is on Green light is off End 7 4 Add user cards by number Press...

Страница 23: ...und stops complete deleting 7 8 Normal Open the door Press 53 CALL The green light is on 7 9 Normally open Press 51 CALL 7 10 Reset normally open Press 53 CALL 7 11 Modify the password Press 0 CALL XX...

Страница 24: ...another operation manual of access control system 8 System Instructions 8 1 The Operation of Outdoor Station 1 Call indoor unit Press 3 digit or 4 digit room number When in communication press Unlock...

Страница 25: ...Err4 S wire short circuit exists in System Err5 Wrong unlock password when enter a password to unlock Err7 The indoor unit has not been encoded Sorry Fail to hang up the phone or household don t want...

Страница 26: ...No 3 digit Unit No 1 digit Room Number 4 digit Total 8 digits Press to exit Setting Press 1 9 any number to add talking time when talking If it shows BUSY the line of guard station is busy Dial later...

Страница 27: ...rk Cable Assembly 1 The multi apartment intercom system supports 485 communication signal 2 There are 6 signal wires NA Audio Intercom NB Audio Intercom TV Video TV Video NT 485 NR 485 3 There are 9 i...

Страница 28: ...Area A D ISN code of Outdoor Station _150 _199 is Building No in Area A E ISN code of Outdoor Station _200 _249 is Building No in Area A F ISN code of Outdoor Station _250 _299 is Building No in Area...

Страница 29: ...d sharp dropping or knocking The image can be illegible for the direct sunshine on the video camera Do not install the product in a humid place It may cause an electric shock or a fire Do not touch th...

Страница 30: ...et simultaneously Do not connect to other products such as TV etc It may cause breakdown Do not disassemble repair or modify the product It may cause a fire an electric shock or an injury to malfuncti...