NOTE: Top Rail and the side Panels are offset to provide 

the proper pitch to the rear of (5/16”). This is necessary for 

proper condensation utilization and drainage. If you are not using the side panels, the rear pitch must still be maintained. 

 
 
 
 

 

1. 

Attach the top rail onto the top of the outer case using four Short Screws. 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TOP RAIL INSTALLATION 

Содержание WC1-05M2-01

Страница 1: ...Model 5 400 BTU Window Air Conditioner Operating Instructions V170217 WC1 05M2 01...

Страница 2: ...ant to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following...

Страница 3: ...metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circui...

Страница 4: ...w Long Screw Curtain Lock Sash Lock Part List Window Air Conditioner 1 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Curtain 2 Sash Lock 2 Foam Seal 1 Long Screw for Window Locking Bracket Curtains...

Страница 5: ...eference only For actual data please refer to the rating label on the back of the unit Model WC1 05M2 01 Power Supply Ph V Hz 1 115 60 Rated Cooling Capacity BTU h 5 400 Cooling Power Input Watts 458...

Страница 6: ...TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN WARNING Avoid fire hazard or electronic shock DO NOT use an extension cord or an adapter plug DO NOT remove any prong from the powe...

Страница 7: ...storm window frame This will allow the air conditioner to tilt enough for proper drainage See FIG 2 MIN FIG 1 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Che...

Страница 8: ...itch to the rear of 5 16 This is necessary for proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be maintained 1 Attach the top rail onto the...

Страница 9: ...s for each side The flange for securing the curtain into the window sill will befac ing the room side when installed 4 Place the curtain lock between the curtain extensions and the window sill drive l...

Страница 10: ...tioner off and disconnect thepower cord 2 Remove the sash seal from between windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels i...

Страница 11: ...rn the selector counter clockwise to select the lower cool settings Turn the MODE selector to OFF to turn off the unit Fan Mode Turn the MODE selector counter clockwise to select HIGH FAN MED FAN or L...

Страница 12: ...t or interrupted the air conditioner will automatically re start in the setting last used prior to power loss Timer will be cancelled when power is lost or interrupted You may need to set a new time i...

Страница 13: ...To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or washed wit...

Страница 14: ...engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds o...

Страница 15: ...tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air...

Страница 16: ...cial handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those au...

Отзывы: