Notice for User

 

1

Please carefully read the label on main machine; if any abnormal conditions detected such as abnormal

 noise, odor, smog, temperature rise, electric leak or fire, please immediately cut off the power supply 

and contact local customer service center or dealer of our company rather than automatic repairing. 

Immediately contact local fire control and first aid department if necessary. 

Notice

!

Warning

!

It may lead to death, serious injury or major accidents due to mistaken operation.

It may lead to safety accident, machine damage or impair the unit operation effect 

due to improper operation. 

!

Warning

1. The unit must not be mounted by own. it must be mounted by the dealer or professional installation 

company authorized by our company; otherwise it may lead to safety accident and impair the 

operation effect. 

2. Unless operation instructed by professional staff, the non-professional staff must not remove the 

unit at will; otherwise it may lead to accident or damage the unit. 

3. Do not operate or store inflammable or explosive articles around or below the unit; otherwise it may 

lead to fire hazard. 

4. The main power supply switch of unit shall be placed in the location unavailable by the child so as 

not to cause hazard. 

5. Do not sprinkle the water or other fluid on the unit; otherwise it may lead to electric leak risk. 

6. Do not touch this unit with wet hand; otherwise it may lead to electric shock. 

7. In stormy weather, please cut off the unit main power supply switch; otherwise it may lead to 

lightning risk and therefore damage the unit due to lightning. 

8. Before long time out-of-work of unit, please cut off the main supply switch so as to avoid accident. 

9. The unit shall use independent power supply switch and special power circuit to avoid common 

circuit with other electric appliances; use the power supply wire with specified section area to 

supply for the unit and equip with the circuit breaker of related specifications (with electric leak 

protection function). 

10. The unit must be mounted with the grounding wire with specified section area and reliably 

mounted; do not connect the grounding wire with the earth wire of gas pipelines, water pipeline, 

arrester conductor or phone so as not to cause accident electric shock. 

11. Do not forcibly cut off the power supply during normal operation of unit so as not to cause 

accident. 

Safety Notice

 

Safety Notice provides the most important safety-related and unit operation key points.Be sure to operate

 accordingly. Meanings of symbols in documents:

Содержание SA-ZM03ENG-1

Страница 1: ...CENTRAL AIR CONDITIONING Full DC Inverter celling mounted cassette type air conditioner Instruction Manual...

Страница 2: ...5 6 Name of air conditioner components Preparation before installation Installation of unit Test run Maintenance and service 21 20 11 8 1 4 7 Symptom analysis and treatment 8 Electric installation 26...

Страница 3: ...e placed in the location unavailable by the child so as not to cause hazard 5 Do not sprinkle the water or other fluid on the unit otherwise it may lead to electric leak risk 6 Do not touch this unit...

Страница 4: ...rious accident 4 In case of failure of unit the user shall timely report to the service center of our company for consultation and repair rather than repairing by himself the repairing of unit by non...

Страница 5: ...ut off the power supply before maintenance of unit 4 Do not touch the exhaust side pipe fittings to avoid scalding since the temperature may be more than 100Centigrade 5 The sharp edge and fin surface...

Страница 6: ...th position of dialing SW2 on the electronic controller shall be turned to ON position as shown in right figure in case of failure of remote controller press emergency key for emergency operation Oper...

Страница 7: ...d direction Timer Lock button Sleep Light button Purification Forced Function description ON OFF key When pressing the key the remote controller circulates in sequence of ON OFF ON Mode key When press...

Страница 8: ...ng the sleep key circulate in sequence of sleep cancel sleep sleep if the sleep mode is activated it will not be canceled after changed the mode It is set as non lock state in default when pressing th...

Страница 9: ...ng conditions it indicates the battery is used up take out the used battery and replace with new one There is no air conditioner receiving sound after transmitted the signal The display screen becomes...

Страница 10: ...at the place where can not be directly exposed to the sunshine if inevitable please mount the sunshade facility to avoid direct exposure to the sunshine 2 The noise and air flow generated by the unit...

Страница 11: ...idth is 1 0 times less than outdoor units When there are barriers at front side and both sides do not use the dimensions shown in the figure Please refer to the right figure Above 300 Above1500 Above...

Страница 12: ...airing the heating or cooling effect and failure due of outdoor unit heat exchanger due to inadequate air flow A When there is wall nearby please locate the air exhaust facing the wall and keep about...

Страница 13: ...ng polyethylene with the thickness of more than 10mm If more than 10mm please collect them at the position of inlet of ceiling 1 This indoor unit can be mounted on the ceiling of 2 5 3 5m high but whe...

Страница 14: ...the ceiling required for installation In case the ceiling is mounted a The dimensions of ceiling opening please refer to installation drawing b Firstly complete all pipelines connecting with indoor un...

Страница 15: ...d to drip B When there is installation position on the ceiling Be sure to use bolt and nut separately at upper and lower head of the hanging bracket seat to firmly fix the hanging bracket seat use loc...

Страница 16: ...t pull down the air return grating and then pull up the other end of button See the figure below 2 Pull up the grating for about 45 degrees and take down the air return grating on trim panel See the f...

Страница 17: ...r return grating and cap A Install the air return grating B Install in reverse sequences to Preparation of trim panel While Install in reverse sequences to Preparation of trim panel While rotating the...

Страница 18: ...tallation notice A Transport the machine parts in origin package state to installation location B Since the outdoor unit weight deflects from center position take care when lifting the machine parts w...

Страница 19: ...tdoor pipelines Quickly fulfill the bell mouth connection operation if placed for long time the dust moisture and foreign matter may ingress and therefore lead to the failure Before tightening the bel...

Страница 20: ...tween hanging bracket If the air conditioner is necessary to transfer to the other position discharge the air with vacuum pump or refrigerant Pressure test vacuumizing and leak test of connecting pipe...

Страница 21: ...300mm from the unit Notice 1 Do not make the attached drainage hose subjected to excess force or bending and twisting It may lead to water leak 2 Please install according to following procedure if sev...

Страница 22: ...ion will be canceled then operate the keys of remote controller to observe whether the operation modes of unit changes correspondingly A Press mode key and select air supply mode check whether there i...

Страница 23: ...ollector or clean with water 3 After cleaning with water place it in shady space for drying 2 Do not dry with the fire otherwise the screen may catch fire The room temperature is set at comfortable te...

Страница 24: ...onditioner 2 Turn off the air conditioner and cut off the special power supply of air conditioner 3 Completely clean the filter screen and indoor unit 4 Take out the battery in remote controller and p...

Страница 25: ...ud The air inlet or outlet of indoor or outdoor unit is blocked Open the door and windows The temperature setting is too high during refrigeration The temperature setting is too low during heating Rem...

Страница 26: ...is 1Hz 7 Symptom analysis and treatment Table 2 Parameter table for spot inspection of outdoor unit The digital tube display the indoor unit amount connected and communicated with during standby The d...

Страница 27: ...H9 Display P9 protection for 2 times within 10 minutes Unable to restore unless a second power on H10 3 times of P3 protection occurs within 60 minutes Unable to restore unless a second power on P1 H...

Страница 28: ...3 The connection method of unit and power supply connection methods and electric works of each independent unit refer to the wiring diagram attached on the unit 4 Please clearly comply with the wirin...

Страница 29: ...supply line Signal wire L1 N1 S L1 N1 S Applicable for 380V 50Hz 10 5kW model N N POWER SUPPLY POWER SUPPLY Outdoor nuit Indoor nuit Note Only the wiring methods of signal line and power supply line a...

Страница 30: ...drainage hose 2 hose clamps 5 ribbons 4 hoisting rods Note The details refer to the actual article Attachment package 2 1 Installation and Operation Instruction including the product after sales servi...

Страница 31: ...on Equipment CO LTD Address Chigo Industrial District Nanhai Foshan Guangdong China P C 528244 Tel 86 757 8836905 Fax 86 757 88783793 4006 757 555 Hotline Web http www chigo cac com CENTRAL AIR CONDIT...

Отзывы: