R410A50Hz Universal Outdoor Series Technical Manual Duct Type Indoor Unit
70
GD Chigo Heating & Ventilation Equipment Co., Ltd.
6.5 CTB-36HR1,CTB-36CR1
MODEL
CTB-36HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
43ºC
21ºC D 15ºC W
Total capacity kW
9.86
9.77
9.67
9.52
8.55
7.26
Input kW.
3.67
3.75
3.94
3.94
4.18
4.35
24ºC D 17ºC W
Total capacity kW
10.36
10.25
10.15
10.00
8.98
7.63
Input kW.
3.75
3.82
3.90
4.02
4.26
4.44
27ºC D 19ºC W
Total capacity kW
10.87
10.76
10.66
10.50
9.42
8.01
Input kW.
3.82
3.90
3.98
4.10
4.35
4.53
29ºC D 19ºC W
Total capacity kW
11.31
11.20
11.08
10.92
9.82
8.33
Input kW.
3.90
3.98
4.06
4.18
4.44
4.62
32ºC D 23ºC W
Total capacity kW
11.76
11.64
11.53
11.36
10.20
8.66
Input kW.
3.98
4.06
4.14
4.26
4.53
4.71
6.6 CTB-48HR1,CTB-48CR1
MODEL
CTB-48HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
43ºC
21ºC D 15ºC W
Total capacity kW
13.15
13.02
12.89
12.70
11.40
9.69
Input kW.
4.78
4.88
5.14
5.14
5.45
5.67
24ºC D 17ºC W
Total capacity kW
13.81
13.67
13.54
13.34
11.97
10.17
Input kW.
4.88
4.98
5.08
5.23
5.55
5.78
27ºC D 19ºC W
Total capacity kW
14.50
14.35
14.21
14.00
12.57
10.68
Input kW.
4.98
5.08
5.18
5.34
5.67
5.90
29ºC D 19ºC W
Total capacity kW
15.08
14.93
14.78
14.56
13.09
11.10
Input kW.
5.08
5.18
5.29
5.45
5.78
6.01
32ºC D 23ºC W
Total capacity kW
15.68
15.52
15.37
15.15
13.60
11.55
Input kW.
5.18
5.29
5.39
5.55
5.90
6.14
6.7 CTB-60HR1,CTB-60CR1
MODEL
CTB-60HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
43ºC
21ºC D
15ºC W
Total capacity kW
15.03
14.88
14.73
14.51
13.03
11.07
Input kW.
5.41
5..52
5.81
5.81
6.16
6.41
24ºC D
17ºC W
Total capacity kW
15.78
15.62
15.47
15.24
13.68
11.62
Input kW.
5.52
5.63
5.75
5.92
6.28
6.54
27ºC D
19ºC W
Total capacity kW
16.57
16.40
16.24
16.00
14.36
12.20
Input kW.
5.63
5.75
5.86
6.04
6.41
6.67
29ºC D
19ºC W
Total capacity kW
17.23
17.06
16.89
16.64
14.96
12.69
Input kW.
5.75
5.86
5.98
6.16
6.54
6.80
32ºC D
23ºC W
Total capacity kW
17.92
17.74
17.57
17.31
15.54
13.20
Input kW.
5.86
5.98
6.10
6.28
6.67
6.94
Содержание CCA-18CR1
Страница 104: ...R410A50Hz Universal Outdoor Series Technical ManualFloor ceiling 101 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 106: ...R410A50Hz Universal Outdoor Series Technical ManualFloor ceiling 103 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 131: ...R410A50Hz Universal Outdoor Series TechnicalManual Outdoor unit 128 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 133: ...R410A50Hz Universal Outdoor Series TechnicalManual Outdoor unit 130 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 135: ...R410A50Hz Universal Outdoor Series TechnicalManual Outdoor unit 132 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 137: ...R410A50Hz Universal Outdoor Series TechnicalManual Outdoor unit 134 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 156: ...R410A50Hz Universal Outdoor Series TechnicalManual Outdoor unit 153 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 176: ...R410A50Hz Universal Outdoor Series Technical ManualController 173 GD Chigo Heating Ventilation Equipment Co Ltd...
Страница 177: ...R410A50Hz Universal Outdoor Series Technical ManualController 174 GD Chigo Heating Ventilation Equipment Co Ltd...