R410A DC Inverter Multi-split Technical Manual
Installation
55
GD Chigo Heating & Ventilation Equipment Co., Ltd.
Part 4.
Installation
1. Installation and Operation Instructions
CAUTIONS
For correct installation read this manual before starting installation and save this manual in a safe place for
future reference.
Only trained and qualified service personnel should install repair or service air conditioning equipment. Users
should not install the air conditioner by themselves.
Nominal cooling capacity of outdoor unit is tested under the condition that outdoor ambient dry/wet bulb
temperature is 35°C/24°C.Actual max. Output capacity depends on outdoor ambient temperature and
connection method, which may differ from nominal value. According to refrigeration system design and
operation requirement, this outdoor unit should work with indoor units with corresponding total capacity, which
ensures optimal performance and safe operation. To meet users' demand, this unit is specially designed that
unit can work even though required total capacity of indoor units exceeds nominal value. Under this condition,
actual output capacity of single indoor unit may be attenuated and less than nominal value. We disclaim all
responsibility for malfunct
ion caused by users’ noncompliance of this installation and operation instructions.
Please read the instructions carefully and follow the requirements below:
1.1 Type of Indoor Unit
Type
Nominal Capacity K Btu/h
CSG-07HVR1(84) (87) (107)
7
CSG-09HVR1(84) (87) (107)
9
CSG-12HVR1(84) (87) (107)
12
CSG-18HVR1(84) (87) (107)
18
1.2 Connection Rules of DC Inverter One-two Split Type
Nominal
Capacity
K Btu/h
One indoor unit
two indoor units
7
7+7
9+9
12+12
9
7+9
9+12
12
7+12
DC inverter multi system connect different style indoor units, includes 84series
、
87series
、
107series. All type
indoor units can be freely combined.