background image

 OLCB1U

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies and its affiliated corporations and 
subsidiaries (collectively "Milestone"), intend to make this 
manual accurate and complete. However, Milestone makes no 
claim that the information contained herein covers all details, 
conditions or variations, nor does it provide for every possible 
contingency in connection with the installation or use of this 
product. The information contained in this document is subject 
to change without notice or obligation of any kind. Milestone 
makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Milestone assumes 
no responsibility for accuracy, completeness or sufficiency of 
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies. 
All rights reserved.

DEFINITIONS

MOUNTING SYSTEM: 

A MOUNTING SYSTEM is the 

primary Chief product to which an accessory and/or component 

is attached.

ACCESSORY: 

AN ACCESSORY is the secondary Chief 

product which is attached to a primary Chief product, and may 

have a component attached or setting on it.

COMPONENT: 

A COMPONENT is an audiovisual item 

designed to be attached or resting on an accessory or mounting 

system such as a video camera, CPU, screen, display, 

projector, etc.

WARNING:  

A WARNING alerts you to the possibility of 

serious injury or death if you do not follow the instructions.

CAUTION:  

A CAUTION alerts you to the possibility of 

damage or destruction of equipment if you do not follow the 

corresponding instructions.

 IMPORTANT SAFETY INSTRUCTIONS

WARNING:  

Failure to read, thoroughly understand, and 

follow all instructions can result in serious personal injury, 
damage to equipment, or voiding of factory warranty! It is the 
installer’s responsibility to make sure all components are 
properly assembled and installed using the instructions 
provided.

WARNING:  

Failure to provide adequate structural strength 

for this component can result in serious personal injury or 
damage to equipment! It is the installer’s responsibility to 
make sure the structure to which this component is attached 
can support five times the combined weight of all equipment. 
Reinforce the structure as required before installing the 
component.

WARNING:  

Exceeding the weight capacity can result in 

serious personal injury or damage to equipment! It is the 
installer’s responsibility to make sure the combined weight of 
all components located within the mounting system of the 

OLCB1U mounts does not exceed 250 lbs (113.4 kg) total or 
125 lbs (56.7 kg) per display.

NOTE:  

"Moment" ratings have NOT been evaluated by UL.

WARNING:  

Exceeding the maximum moment can result in 

serious personal injury or damage to equipment! It is the 
installer’s responsibility to make sure the mounting system 
does not exceed a moment of 2000 ft-lbs. See table below for 
specific column specifications.

WARNING:  

Never operate this mounting system if it is 

damaged. Return the mounting system to a service center for 
examination and repair.

WARNING:  

Use this mounting system only for its intended 

use as described in these instructions. Do not use 
attachments not recommended by the manufacturer.

WARNING:  

Never operate this mounting system if it is 

damaged. Return the mounting system to a service center for 
examination and repair.

WARNING:  

Use this mounting system with other outdoor 

products only.

WARNING:  

Always use two people or a mechanical lifting 

device to safely lift and position equipment.

NOTE:  

The OLCB1U flat panel floor/ceiling mounts are 

intended to be used with UL Listed ODAC Series 
columns (not included): ODAC0203, ODAC0304, 
ODAC0405, ODAC0506, ODAC0708.

--SAVE THESE INSTRUCTIONS--

COLUMN 
MODEL

Weight 
capacity

Moment 
Length (IN) 
(ML) 

Max 
Design 
Moment 
(FT-LBS) 
(MDM)

ODAC0203B

300 lbs (136 kg)

23 min - 36 max

2000

ODAC0304B

300 lbs (136 kg)

33 min - 48 max

2000

ODAC0405B

300 lbs (136 kg)

45 min - 60 max

2000

ODAC0506B

300 lbs (136 kg)

57 min - 72 max

2000

ODAC0708B

300 lbs (136 kg)

81 min - 96 max

2000

125

125

Содержание OLCB1U

Страница 1: ...stalled to ODAC Series extension column Back to Back Large Flat Panel Outdoor Ceiling Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description OLCB1U ...

Страница 2: ...ARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity...

Страница 3: ...Installation Instructions OLCB1U 3 DIMENSIONS DIMENSIONS INCHES MILLIMETERS 1 91 48 4 0 HOLE LOCKOUT 5 AND 15 HOLE LOCKOUT 5 AND 20 HOLE LOCKOUT 7 6 HOLE LOCKOUT 10 2 48 63 0 10 HOLE LOCKOUT ...

Страница 4: ...chraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Open Ended Wrench Llave de boca Gabelschlüssel Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Adjust Ajustar Einstellen Ajustar...

Страница 5: ... per bag B 4 C 4 A 4 F 4 G 4 J 1 M6x25mm M8x20mm M8x30mm M6x16mm 750x 323x 250 750x 344x 500 5 16 L 4 Interface bracket 1 4 20 x 1 1 4 H 1 Mount assembly P 1 5 16 18 x 2 W 4 3 8 N 1 1 4 20 x 2 Q 1 1 4 20 R 1 5 16 18 S 2 5 16 T 2 1 4 U 2 3 8 16 x 4 V 2 3 8 16 M 1 10 24 x 1 2 Interface Lockout Bag 4 Qty per bag Box column Hardware Kit K 1 5 32 ...

Страница 6: ...OR PINCH POINTS Do not place fingers between movable parts 1 Slide mount assembly H onto ODAC Series Floor Ceiling Column See Figure 1 or See Figure 2 2 Use two 3 8 16 x 4 hex head tapping bolts U four 3 8 washers W and 3 8 16 hex nuts V See Figure 1 or See Figure 2 Figure 1 Figure 2 3 Install 1 4 20 x 1 1 4 button head cap screw J into mount assembly H to prevent column from rattling See Figure 3...

Страница 7: ...een See Figure 5 Attaching Display to Ceiling Mount WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located within the mounting system of the OLCB1U mounts does not exceed 250 lbs 113 4 kg total or 125 lbs 56 7 kg per display 1 Ensure that the latch mechanisms ...

Страница 8: ...direction 1 Remove two bolts and washers connecting column collar to mount assembly box See Figure 8 2 Adjust yaw in 45 increment until desired position is achieved See Figure 8 3 Reinstall bolts and washers removed in Step 1 See Figure 8 Figure 8 Tilt CAUTION Watch for pinch points Do not place fingers between movable parts The interface brackets allow 7 6 to 20 tilt and can be locked at 7 6 5 0 ...

Страница 9: ... Figure 11 Figure 11 Latch Lock Security IMPORTANT In order to prevent interface latch from getting loose due to strong winds the latch MUST be locked either using a padlock or locking bolt N and 5 16 18 hex nuts Q This is NOT optional Using Padlocks Security 1 Add padlock not included to each interface bracket to lock latch and to provide security for displays See Figure 12 Figure 12 Using Bolts ...

Страница 10: ...OLCB1U Installation Instructions 10 ...

Страница 11: ...Installation Instructions OLCB1U 11 ...

Страница 12: ...ope A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief Manufacturing a products division of Milestone AV Technologies 8800 003021 Rev01 2018 Milestone AV Technologies www milestone com 12 18 ...

Отзывы: