background image

I N S T A L L A T I O N   I N S T R U C T I O N S

Interactive Flat Panel Over White Board Mount

Spanish Product Description
German Product Description

 Portuguese Product Description

 Italian Product Description

Dutch Product Description

French Product Description

OB1U

Содержание OB1U

Страница 1: ...R U C T I O N S Interactive Flat Panel Over White Board Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description OB1U ...

Страница 2: ...ONS WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all mounting systems are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this mounting system can result i...

Страница 3: ...Installation Instructions OB1U 3 DIMENSIONS DIMENSIONS INCHES MILLIMETERS ...

Страница 4: ...m D1 4 M8x12mm E1 4 M8x20mm F1 4 M8x30mm G1 8 H1 4 Universal washer L 10 Drywall anchor R 4 Bumper plate retainer X 1 Cross bracket V 2 Lower wall bracket T 1 Wall assembly assembly Optional Spacer XL Display Hardware Kit A 2 1 4 20 x 1 2 B 2 1 4 20 x 3 8 C 4 1 4 20 x 3 4 D 2 1 16 E 2 1 4 20 G 10 1 4 H 1 5 32 I 10 1 4 20 x 1 3 4 J 10 1 4 x 2 1 2 K 10 UX8 x 50R M 4 Bumper N 4 4 knob U 2 Lower brack...

Страница 5: ...the mount is being attached is capable of supporting five times the weight of the OB1U and all attached equipment not to exceed 310 lbs 140 6 kg WARNING ELECTRICAL SHOCK EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO ELECTRICAL CORDS CABLES OR GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of electrical wires cables gas water wa...

Страница 6: ...assembly T AND a minimum of 16 from both outside wall brackets NOTE Leave a minimum of 1 between the bottom of the wall assembly brackets and the top of the existing chalkboard whiteboard This will allow enough space to install the wall bracket covers Q at a later time 2 Using the wall assembly T mark the wall above existing chalkboard whiteboard through mounting holes in each bracket See Figure 5...

Страница 7: ...lled to a minimum of one stud left and right of the stud s being used to install the mount Drywall must be secured to studs with screws a maximum of 12 305mm apart down center of stud Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Members 362 S 125 18 C Shaped S Stud Section See hazard statement on page 2 Drywall 1 ...

Страница 8: ... Repeat Steps 5 through 8 for each mounting hole Figure 10 10 Place wall brackets of wall assembly T over installed anchors and align mounting holes in wall brackets with holes in anchors See Figure 11 11 Insert 1 4 20 x 1 3 4 Phillips pan head screws I through 1 4 washer G corresponding mounting hole on wall bracket and into anchor L and tighten until flush against wall bracket DO NOT over tighte...

Страница 9: ...et X by inserting two 1 4 20 x 3 4 button head flange screws C through lower mounting holes in cross bracket See Figure 13 5 The mounting system may be laterally shifted by moving the upright assemblies P laterally along the wall assembly T to the desired location 6 Tighten the button head cap screws on the wall brackets to fasten the wall assembly in place See Figure 12 Figure 13 7 Move the slide...

Страница 10: ...r being installed The center of interface bracket is indicated by the diamond shaped hole See Figure 16 3 Pull down on interface bracket handles to open for attaching to OB1U See Figure 15 4 Hang flat panel with attached interface brackets onto the cross bracket X ensuring that one interface bracket is on each side of the cross bracket center line CL See Figure 16 NOTE Two slots on cross bracket i...

Страница 11: ...ng cover S down over the wall bracket cover Q on three wall assembly brackets See Figure 19 Figure 19 Completing Attachment to Wall IMPORTANT See Adjustment and Leveling of Micro Height Adjust and Adjustment of Lower Leg Plumb sections to make any necessary adjustments BEFORE completing attachment to wall NOTE The lower part of the OB1U must be attached to the wall using the correct hardware for t...

Страница 12: ...See Figure 21 Figure 21 4 Hold metal channel on drywall anchor L flat alongside plastic straps and slide channel through hole See Figure 22 Figure 22 5 Holding plastic straps on drywall anchor L pull anchor away from wall until channel rests flush behind wall See Figure 23 6 Slide plastic cap on anchor L towards wall until flange of cap is flush with wall See Figure 23 Figure 23 7 Snap off plastic...

Страница 13: ...5 Rotate the lower wall bracket back into place 6 Use two 1 4 x 2 1 2 lag bolts J and two 1 4 flat washers F to attach each lower wall bracket V to anchors in wall See Figure 26 Adding Stabilizing Hardware 1 Attach two bumper plate retainers R two 4 knobs N and two bumpers M through each leg assembly one just below top of flat panel and one just above bottom of flat panel See Figure 27 2 Adjust 4 ...

Страница 14: ...allation Instructions 14 Adjustment of Lower Leg Plumb 1 Turn the buttonhead screw at bottom of leg if necessary to adjust the plumb on lower leg so that it sets firmly against the wall See Figure 29 Figure 29 1 ...

Страница 15: ...Installation Instructions OB1U 15 ...

Страница 16: ...003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 OB1U Installation Instructions Chief a products division of Milestone AV Technologies 8800 003010 Rev00 2017 Milestone AV Technologies www milestone com 12 17 ...