4.

Adjust Centris bracket (B) to desired height and tighten the
knob closest to the array (A1) to secure Centris bracket to
array. (See Figure 6)

NOTE:

If installing a KWP230, adjust two Centris brackets (B)
to desired height following instructions in Step 4.

Figure 6

5.

Install 1/4-20" square nut (F) into the top of the back groove
of array (A1 or A2) and line up with top hole on plate. (See
Figure 7)

6.

Install 1/4-20 x 1/2" button head cap screw (D) into upper
hole on array and through square nut (F). (See Figure 7)

Figure 7

Display Installation

The mounting holes on the back of your display will either be

flush with

 the back surface, or

recessed into

 the back surface.

Refer to the applicable installation procedure.

WARNING:

Exceeding the weight capacity can result in

serious personal injury or damage to equipment!  It is the
installer’s responsibility to make sure the combined weight of
all components attached to this accessory does not exceed
40 lbs (18.14 kg) for the KWP130, and 16.5 lbs (7.5 kg) per
display for the KWP230.

FLUSH MOUNTING HOLES

CAUTION:

Using screws of improper size may damage

your display!  Proper screws will easily and completely thread
into display mounting holes.

CAUTION:

Inadequate thread engagement in display may

cause display to fall!  Back out screws ONLY as necessary to
allow installation of Centris bracket!

1.

Ensure Centris bracket is able to swivel and tilt easily, yet
still be tight enough to hold display in desired position.
Adjust as required before proceeding.  See

Adjustments

section for detail.

2.

Using Phillips screwdriver, carefully install two M4 x 12mm
Phillips pan machine screws (L) into the

upper

 mounting

holes on the display.  Thread screws completely into
display, then back out 3 complete turns.

3.

Pick up and align display so that screws (L) (installed on the
back of the display in the previous step) fit into the mounting
holes on the Centris bracket; rotate the bracket as required.
Lower the display firmly into place. (See Figure 8)

Figure 8

4.

Using Phillips screwdriver, install two remaining M4 x 12mm
Phillips pan machine screws (L) through the

lower

 mounting

holes in Centris bracket into the display.

5.

Tighten all four screws (L).  Do not overtighten!

RECESSED MOUNTING HOLES

1.

Carefully place display face down on protective surface.

2.

Determine depth of recessed mounting holes relative to
back surface of display (against which Centris head will
contact).

Height adjustment

knob

(F)

(D)

6

5

(KWP130 shown)

(A1 or A2)

(L) x 2

(B)

Содержание KWP130

Страница 1: ...ação Istruzioni di installazione Installatie instructies Instructions d installation KWP130 KWP230 Single and Dual Array Vertical Wall Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description KWP130 KWP230 ...

Страница 2: ...ssibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WAR...

Страница 3: ...issaggio Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro ...

Страница 4: ...mount Wall bracket Centris bracket H 1 5 32 J 5 x 194 x 375 D 2 1 4 20 x 1 2 E 2 10 x 2 1 2 F 2 1 4 20 G 2 10 K 5 x 194 x 75 L M4 x12mm M4 x 20mm N M4 x 30mm Array Hardware Kit KWP130 only M Quantities of 4 each for KWP130 Quantities of 8 each for KWP230 A2 1 17 Vertical array wall mount KWP230 only KWP130 qty 1 KWP230 qty 2 1 8 ...

Страница 5: ...proper engaging of set screw in Step 5 4 Insert top of mount A1 or A2 over lip on top of bracket C Swing mount A1 or A2 down flush against wall See Figure 2 Figure 2 5 Tighten set screw using 5 32 hex key H Ensure set screw engages back side of bracket C to properly secure mount See Figure 3 Figure 3 Centris Bracket to Array IMPORTANT If you will be installing a display with RECESSED mounting hole...

Страница 6: ...per screws will easily and completely thread into display mounting holes CAUTION Inadequate thread engagement in display may cause display to fall Back out screws ONLY as necessary to allow installation of Centris bracket 1 Ensure Centris bracket is able to swivel and tilt easily yet still be tight enough to hold display in desired position Adjust as required before proceeding See Adjustments sect...

Страница 7: ...install four selected screws M or N through the mounting holes in Centris bracket through the spacers J or K into the display See Figure 9 Tighten all four screws Do not overtighten 7 Return to Centris Bracket to Array section to complete installation Adjustments If previously attached disconnect cables from display then remove display VERTICAL POSITION ON ARRAY 1 Using your fingers slightly loose...

Страница 8: ...Company www chiefmfg com 07 09 USA International A 8401 Eagle Creek Parkway Savage MN 55378 P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 8996 9217 ...

Отзывы: