background image

CMSI

Installation Instructions

6

INSTALLATION

1.

Determine mounting location of the CMSI.

IMPORTANT ! :

The CMSI should be centered above the

whiteboard, and be located a minimum of 14" (355.6mm)
above the whiteboard. (See DIMENSIONS drawing for
further information.) The whiteboard should have a
maximum thickness of 1.33" (33.8mm) or less.

2.

Using the sensor assembly (D) as a template, mark two
holes through the holes in the assembly.

3.

Proceed to appropriate wall type for further instruction.

WARNING:

ELECTRICAL SHOCK HAZARD! CUTTING

OR DRILLING INTO ELECTRICAL CORDS OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surface is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.

WARNING:

EXPLOSION AND FIRE HAZARD! CUTTING

OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surface is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.

Concrete Wall

1.

Drill two 3/8" holes at marked locations in wall. (See Figure 1)

Figure 1

2.

Install two concrete anchors (BC) into drilled holes. (See
Figure 1)

3.

Install two 5/16 x 2-1/2" hex head lag screws (BA) through
two 5/16" washers (BB), middle section of mounting holes
in sensor assembly (D) and into concrete anchors (BC).
(See Figure 1)

Wood Studs

IMPORTANT ! :

The wall to which the mount is being

attached may have a maximum drywall thickness of 5/8"
(1.6cm).

1.

Drill two 7/32" holes at marked locations in wall.  (See
Figure 2)

Figure 2

2.

Install two 5/16 x 2-1/2" hex head lag screws (BA) through
two 5/16" washers (BB), middle section of mounting holes
in sensor assembly (D) and into drilled holes. (See Figure 2)

Drywall Only

IMPORTANT ! :

Do not install drywall anchors into the seam

between drywall pieces.

3.

Install two 08 x 2" Phillips head screws (F) through smallest
part of mounting holes in sensor assembly (D) and into
drywall. (See Figure 2)

1

x 2

(BC) x 2

2

(D)

3

(BA) x 2

(BB) x 2

middle section of
mounting hole

2

(BA) x 2

(BB)

(F) x 2
(drywall only installation)

(wood stud installation)

1

3

smallest part
of mounting
hole

(D)

Содержание CMSI

Страница 1: ...R U C T I O N S Interactive Upgrade Kit Ceiling Projector Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description F...

Страница 2: ...oroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all component...

Страница 3: ...uctions CMSI 3 DIMENSIONS 3 00 76 2 140 SENSOR COVERAGE RECOMMENDED 14 00 355 6 MIN TO TOP OF WHITEBOARD 7 40 188 0 14 00 355 6 RECOMMENDED WHITEBOARD THICKNESS APPROXIMATE SENSOR COVERAGE DIMENSIONS...

Страница 4: ...Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche By Hand A mano Von Hand Com a m o A mano Met de hand la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a...

Страница 5: ...ctive Kit AA 1 Stylus replacement tip kit 4 tips AB 1 Stylus AC 1 Interactive software AD 1 AAA battery AE 1 Quick start guide AF 1 Stylus wrist strap kit AG 1 Interactive USB cable B Mounting Kit BA...

Страница 6: ...her plumbing before cutting drilling or installing fasteners Concrete Wall 1 Drill two 3 8 holes at marked locations in wall See Figure 1 Figure 1 2 Install two concrete anchors BC into drilled holes...

Страница 7: ...x 7 ft or up to 94 inches diagonal measure The minimum active capture area supported is 1 7 ft x 1 1 ft Connection Requirement The CMSI includes a USB cable Screen Recording Requirements Currently av...

Страница 8: ...straat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 447...

Отзывы: