Installation Instructions
CM6DV SERIES
7
Testing Doors for Fit
It is of upmost importance that the doors on the cabinet are of
the same weight and that they move freely without obstruction.
To test doors:
1.
Remove the 4 red shipping screws from Wheel Plates.
(Save for futureshipping use.)
NOTE:
The doors should remain motionless. If the doors start
toclose the top door is too heavy, if they start to open
the bottom door is too heavy. Make corrections until the
doors are balanced.
2.
While holding the Chain Attach bracket away from the plate,
grasp the top door and move it open. (The doors should
move freely without any restriction.)
3.
If both of these requirements are met, connect the Chain
Attach bracket to the plate using the nylon thumbnuts on the
mounting studs.
IR Sensor Placement
The placement of the IR sensor can be crucial to proper
operation of the system. A flexible IR sensor is provided to
make it easier to achieve reliable operation.
In most applications, the IR sensor may be installed on top of
the cabinet. However, tall ceilings and/or dark colored ceilings
can absorb the IR signal. If inconsistent operation is
encountered there are two alternatives.
•
One, the flexible IR sensor eye can be placed so that it
gives the sensor "line of sight" to the signal from the
remote controller. Often this merely involves placing
the IR sensor so that it peeks up over the top of the
cabinet. It doesn't have to be much, just enough to give
"line of sight".
•
Two, an IR sensor extension cord can be used to
position the IR sensor in the cabinet near to the other
remote controlled units. (For example, near to the VCR
or DVD player)
Install Light Dimmer Module (Optional)
With the dimmer option installed cabinet lighting can be
switched on or off or dimmed using the left buttons on the
systems remote control.
To install the optional dimmer:
1.
Plug 115VAC lighting into the back of the Light Dimmer
Module.
2.
Plug the other end of Dimmer Module cord into a 115VAC
grounded receptacle on motor assembly.
CAUTION:
The Dimmer is for 120 volt incandescent or
Halogen lamps of at least 25 watts and should not to exceed
300 watts total.
The system also provides the option of creating and saving two
different lighting "scenes". Please refer to the Remote Control
instructions for information on how to configure "scenes".
Figure 4
System Activation
1.
Insert plug from the power supply into the jack on the top of
the motor box.
Figure 5
2.
Plug Powercord into 115VAC outlet.
IMPORTANT ! :
A quality surge protection device is
recommended.
3.
Make sure nothing is obstructing movement of doors,
From Dimmer Module
24VDC Input
Top of
Cabinet
Front of
Cabinet