6
7
Steam steriliser for microwave ovens
SterilNaturalMaxi
Dear customer,
We thank you and congratulate you on your
choice. The SterilNatural Maxi steriliser for micro-
wave ovens sterilises naturally with steam without
any chemical additives while ensuring extreme
ease of use. It eliminates 99.9% of harmful domes-
tic germs. It is easy to use and can hold up to 5
Chicco feeding bottles and related accessories
(cap rings, teats and cups).
DESCRIPTION
(fig. 1)
a) lid
b) Rack unit
c) Base
d) Grippers
INSTRUCTIONS FOR USE
1. Clean the steriliser thoroughly before use.
2. Always carefully wash and rinse the objects to
be disinfected before placing them inside the
steriliser.
3. Detach the rack unit (b) from the base (c) of the
steriliser.
4. Pour 200 ml of water into the central part of the
base (c) (fig. 2).
5. Fit the rack unit (b) again on the base (c) (fig. 3)
6. Insert the disassembled feeding bottles in the
rack unit (b). If possible, place the feeding bot-
tles upside down and the accessories in the free
space. If the height of the feeding bottles placed
vertically does not allow the lid (a) to close, lay
the feeding bottles on their side in the rack unit
(b) trying to leave their neck unobstructed by
other objects.
7. Close the steriliser lid (a) and place it in the mi-
crowave.
8. Set the power on the microwave following the
instructions in the table below.
STERILISATION TIMES AND POWERS
Minutes
Watt
3
1200 W
5
840 W
8
600 W
9. When the sterilisation cycle is over, we recom-
mend waiting a few minutes and always use
suitable equipment to protect your hands.
10. Wait for at least a few minutes at the end of
each sterilising cycle, before removing the lid
(a) and always do so carefully to prevent boil-
ing steam or drops of extremely hot water
from exiting the appliance and causing burns.
11. We recommend taking the sterilised objects
out of the microwave using the supplied grip-
pers (d) (fig. 4) and always wash your hands
thoroughly before handling the sterilised ob-
jects.
NB:
disinfected items will remain sterile inside the
steriliser with the lid (a) on for about 24 hours. If
the lid (a) is removed during or after use, the disin-
fection status will be interrupted.
CLEANING & MAINTENANCE
Clean and dry the steriliser thoroughly after use.
The parts of the steriliser can be washed normally,
including in the dishwasher with a delicate cycle.
Do not use abrasive sponges or detergents for
cleaning the steriliser.
During normal use, at the bottom of the base (c)
of the steriliser, a more or less thick layer of lime-
scale film may form depending on the hardness of
the water. If so, clean with white vinegar or lemon
juice diluted in water (possibly leaving to act over
night) and rinse thoroughly.