Air Supply Requirements
1. Supply tool with 90 psig (6.2 bar) of clean, dry air.
Higher pressure drastically reduces tool life.
2. Connect tool to air line using pipe, hose, and
fitting sizes shown in the diagram.
Lubrication
1. Use an air line lubricator with SAE #10 oil,
adjusted to two (2) drops per minute. If an air line
lubricator cannot be used, add air motor oil to the
inlet once a day.
2. Make sure adequate lubrication is provided for
internal gears for long life.
Maintenance
1. Disassemble and inspect air motor every three
months if the tool is used every day. Replace
damaged or worn parts.
2. High wear parts are underlined in the parts list.
English
EN
EC DECLARATION OF CONFORMITY
We, Chicago Pneumatic Tool Company, 1800 Overview
Drive, Rock Hill, SC 29730 USA, declare under our sole
responsibility that the product to which this declaration
relates, is in conformity with the requirements of the
Council Directive of June 1998 on the approximation of
the laws of the Member States relating to machinery
(98/37/EC).
Machine Name
CP7300 1/4 Inch Air Drill
Machine
Type
Power tool equipped with 1/4" chuck
for use with various drill bits for drilling holes - No
other use is permitted.
Serial
No.
Tools with No. 02319P or higher
Technical
Data
Free speed 2800 RPM
Air pressure 90 psi (6.2 bar)
Harmonized
Standards
Applied
EN292
National
Standards
Applied
ISO 8662-1,
Name
And
Position
Of
Issuer
Yves Antier, General
Manager, Chicago Pneumatic Tool Company
Signature
Of
Issuer
Place
And
Date
Of
Issue
Rock Hill, SC 29730 USA,
Novemeber 1, 2002
Noise & Vibration Declaration*
Sound pressure level 86 dB(A),uncertainty 3 dB(A), in
accordance with ISO 15744. For sound power, add
11 dB(A).
2
Vibration value <2.5 m/s , re. ISO 8662-1.
*These declared values were obtained by laboratory
type testing in compliance with the stated standards
and are not adequate for use in risk assessments.
Values measured in individual work places may be
higher than the declared values. The actual exposure
values and risk of harm experienced by an individual
user are unique and depend upon the way the user
works, the workpiece and the workstation design, as
well as upon the exposure time and the physical
condition of the user. We, Chicago Pneumatic,
cannot be held liable for the consequences of using
the declared values, instead of values reflecting the
actual exposure, in an individual risk assessment in
a
work place situation over which we have no control.
ISO15744
1/2" (12mm)
3/8" (10mm)
3/8" (10mm)
3/8" (10mm)
CA048361 (1/2")
CA048362 (1/2")
CA048360 (1/2")
3/8" (10mm)
3/8" (10mm)
130
90
0