Page 14
SKU 96617
For technical questions, please call 1-800-444-3353.
installation instructions
Electrical and other permits may be required for the installation of emergency or
portable power systems. Investigate local building and electrical codes before
installing this unit.
Prior to using Generator to power tools and equipment, make sure the
Generator’s rated voltage, wattage, and amperage capacity is adequate to supply
all electrical loads the unit will power. If powering needs exceed the Generator’s
capacity, it may be necessary to group one or more of the tools/equipment for
connection to a separate Generator.
It is recommended that the Generator be located; outdoors only, where fresh air
is readily available. Locate the Generator so that the air inlets and outlets are
not blocked by obstructions such as bushes, trees, or snow drifts. Locating it in
the path of heavy winds or snowdrifts may require the placement of a barrier for
protection. The air inlet (on Air Cleaner Cover 2R), in normal weather conditions,
should face the prevailing wind direction.
Locate the Generator on a concrete slab or other area where rain drainage or
flood waters cannot reach it.
Generator placement should allow four feet of access to all sides for
maintenance and for proper air cooling.
Place the Generator as close as possible to the electrical tools and equipment
being powered to reduce the length of extension cords.
grounding the generator:
grounding
terminal
#6 awg grounding
wire (not included)
grounding rod
(not included)
Figure c
note:
It is recommended that only a trained and licensed electrician perform this
procedure.
1.
2.
3.
4.
.
6.