Page 9
For technical questions, please call 1-800-444-3353.
SKU 95004
Make sure the extension cord is properly
7.
wired and in good electrical condition.
Always replace a damaged extension
cord or have it repaired by a qualified
electrician before using it.
Protect the extension cords from sharp
8.
objects, excessive heat, and damp or
wet areas.
RECOMMEndEd MInIMUM WIRE gAUgE
FOR EXTEnSIOn CORdS*
(120/240 VOLT)
nAMEpLATE
AMpERES
(at full load)
EXTEnSIOn CORd
LEngTH
25’ 50’ 75’ 100’ 150’
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
TABLE A
* Based on limiting the line volt-
age drop to five volts at 150% of
the rated amperes.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
A
Amperes
n0 xxxx/min.
No Load Revolutions per Minute
(RPM)