Item 94338

        

SAFET

y

Op

ERA

TION

M

AINTENAN

c

E

SETU

p

9. WARNING: Handling the cord on this product will 

expose you to lead, a chemical known to the State 

of California to cause cancer, and birth defects or 

other reproductive harm. Wash hands after handling.  

(California Health & Safety Code § 25249.5, 

et seq.

)

10.

Take caution as some woods contain 

preservatives such as copper chromium 

arsenate (ccA) which can be toxic

. When 

cutting these materials extra care should be taken 

to avoid inhalation and minimize skin contact.

11. Exposure to aluminum oxide (a dust generated 

from material removing processes) can result in 

eye, skin, and respiratory irritation.  Always use 

a NIOSH (National Institute for Occupational 

Safety and Health) approved respirator and ANSI 

approved safety goggles.  Avoid skin exposure.  

Proper ventilation in the work area is required.

12. The warnings, precautions, and instructions 

discussed in this instruction manual cannot cover all 

possible conditions and situations that may occur.  

It must be understood by the operator that 

common sense and caution are factors 

which cannot be built into this product, 

but must be supplied by the operator.

Vibration Safety

This tool vibrates during use.  

Repeated or long-term exposure to vibration may 

cause temporary or permanent physical injury, 

particularly to the hands, arms and shoulders.  

To reduce the risk of vibration-related injury:

1. Anyone using vibrating tools regularly or for 

an extended period should first be examined 

by a doctor and then have regular medical 

check-ups to ensure medical problems are not 

being caused or worsened from use.  Pregnant 

women or people who have impaired blood 

circulation to the hand, past hand injuries, 

nervous system disorders, diabetes, or 

Raynaud’s Disease should not use this tool.  

If you feel any symptoms related to vibration (such 

as tingling, numbness, and white or blue fingers), 

seek medical advice as soon as possible.

2. Do not smoke during use.  Nicotine reduces 

the blood supply to the hands and fingers, 

increasing the risk of vibration-related injury.

3. Wear suitable gloves to reduce the 

vibration effects on the user.

4. Use tools with the lowest vibration 

when there is a choice.

5. Include vibration-free periods each day of work.

6. Grip tool as lightly as possible (while still keeping 

safe control of it).  Let the tool do the work.

7. To reduce vibration, maintain the tool as 

explained in this manual.  If any abnormal 

vibration occurs, stop use immediately.

 SAVE THESE INSTRUcTIONS.

Содержание 94338

Страница 1: ......

Страница 2: ...n which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMpORTANT SAFETy INFORMATION General power Tool Safety Warnings Read all safety warni...

Страница 3: ...alcohol or medication A moment of inattention while operating power tools may result in serious personal injury 2 Use personal protective equipment Always wear eye protection Safety equipment such as...

Страница 4: ...ander Safety Warnings 1 Maintain labels and nameplates on the tool These carry important safety information If unreadable or missing contact Harbor Freight Tools for a replacement 2 Avoid unintentiona...

Страница 5: ...t but must be supplied by the operator Vibration Safety This tool vibrates during use Repeated or long term exposure to vibration may cause temporary or permanent physical injury particularly to the h...

Страница 6: ...to carry electricity away from the user reducing the risk of electric shock See 3 prong plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the gro...

Страница 7: ...an extension cord outdoors make sure it is marked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical c...

Страница 8: ...ERIOUS INJURy REVENT SERIOUS INJUR FROM A y FROM A y ccIDENTAL OpERATION Make sure that the Trigger is in the off Trigger is in the off Trigger position and unplug the tool from its electrical outlet...

Страница 9: ...nd Work Area Set Up 1 Designate a work area that is clean and well lit The work area must not allow access by children or pets to prevent distraction and injury 2 Route the power cord along a safe rou...

Страница 10: ...ed if equipped 4 Internal damage or wear Carbon brushes or Trigger for example 1 Check that cord is plugged in 2 Check power at outlet If outlet is unpowered turn off tool and check circuit breaker If...

Страница 11: ...Gasket 1 21 Screw M5x8 1 22 Pad 1 23 Cord anchorage Cord anchorage 1 24 Screw 2 25 Cord guard Cord guard 1 26 Power cord and plug Power cord and plug 1 27 Label 1 28 Screw ST4 2x20 8 29 Dust bag Dust...

Страница 12: ...ue directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance W...

Отзывы: