Page 5

SKU 94280

For technical questions, please call 1-800-444-3353.

Avoid electrical shock.  

Make sure the Floor Machine is unplugged 

from its electrical outlet prior to performing any inspection, maintenance, 
or cleaning procedures.  Do not use the Floor Machine in the rain or in 
wet conditions.  Plug the Power Cord of this unit only into a 3-hole, 115 
volt, Ground Fault Circuit Interrupter (GFCI), electrical outlet for addi-

tional protection from electric shock.

Use the right product for the job.  

There are certain applications for which this 

product was designed.  Do not use small tools, equipment, or accessories to do the 
work of larger industrial tools, equipment, or accessories.  Do not use this product 
for a purpose for which it was not intended.

Do not allow children or other unauthorized people to handle or play with 
this product.

Industrial applications must follow OSHA requirements.

To reduce the risk of fire, use only commercially available floor cleaners and 
waxes.

WARNING!  

People with pacemakers should consult their physician(s) before 

using this product.  Electromagnetic fields in close proximity to a heart pacemaker 
could cause interference to or failure of the pacemaker.  In addition, people with 
pacemakers should adhere to the following:  Avoid operating power tools alone.  
Don’t use a power tool with the Power Switch locked on.  If powered via a Power 
Cord be certain that the tool is properly grounded.  A ground fault interrupt (GFCI) 
system is also a good precaution.  This inexpensive device is a good safety measure 
because it prevents a sustained electrical shock.  Properly maintain and inspect all 
tools before use to avoid electrical shock.

WARNING!  

The warnings and cautions discussed in this manual cannot cover 

all possible conditions and situations that may occur.  It must be understood by the 
operator that common sense and caution are factors which cannot be built into this 
product, but must be supplied by the operator.

SAVE THESE INSTRUCTIONS

6.

.

8.

9.

10.

11.

12.

Содержание 94280

Страница 1: ... rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions please call 1 800 444 3353 TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE Due to continuing improvements actual product may differ slightly from the product descr...

Страница 2: ...spection maintenance and cleaning procedures parts list and assembly diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Keep this manual and invoice in a safe and dry place for future reference GENERAL SAFETY RULES WARNING READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed below may result in electric shock fire and or s...

Страница 3: ... power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock Do not abuse the Power Cord Never use the Power Cord to carry the tools or pull the Plug from an outlet Keep the Power Cord away from heat oil sharp edges or moving parts Replace damaged Power Cords immediately Dam aged Power Cords increase the risk of electric shock When operating a power t...

Страница 4: ... product use only identical replacement parts Follow instructions in the Inspection Maintenance And Cleaning section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury SPECIFIC SAFETY RULES Maintain labels and nameplates on the Floor Machine These carry important information If unreadable or missing contact Harbor Fr...

Страница 5: ...o reduce the risk of fire use only commercially available floor cleaners and waxes WARNING People with pacemakers should consult their physician s before using this product Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker In addition people with pacemakers should adhere to the following Avoid operating power tools alone Don t us...

Страница 6: ...rry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live terminal See 3 Prong Plug and Outlet You...

Страница 7: ...pacity of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord See Table A When using more than one extension cord to make up the total length make sure each cord contains at least the minimum wire size required See Table A If you are using one extension cord for more than one tool add the nameplate am peres and use the sum to determine the required minimum cord siz...

Страница 8: ...6 0 14 12 10 16 1 20 0 12 10 TABLE A Based on limiting the line voltage drop to five volts at 150 of the rated amperes Symbology Double Insulated Canadian Standards Association Underwriters Laboratories Inc V Volts Alternating Current A Amperes n0 xxxx min No Load Revolutions per Minute RPM UNPACKING When unpacking check to make sure all the parts shown on the Parts List at the end of the manual a...

Страница 9: ... and gently press the tab on the Screw Box 10 from underneath using a screwdriver see lower left Remove the Screw Box Tab Handle Screw 11 storage hole transport hole Align the mounting holes in the lower portion of the Handle Tube 21 with the front two mounting holes in the bracket at the rear of the Floor Machine s Chassis 1 This is the location that the Handle Screw is shown to the top left Then...

Страница 10: ...ing the floor surface after wax has been ap plied Set the Carpet Brush 51 Floor Brush 52 or Pad 54 level on the floor surface See Figure E next page With both hands pick up the Chassis 1 of the Floor Machine and align the machine s Brush Holder Pad 35 with the Carpet Brush 51 Floor Brush 52 or Pad 54 Then push down firmly on the Chassis to secure the Brush or Pad in place NOTE The Brushes and Foam...

Страница 11: ...Handle 26 firmly with both hands Then turn the Power Switch 29 to its ON position and allow the Brush Holder Pad 35 to orbit at full speed See Figure E Slowly move the Floor Machine in broad sweeping strokes in a criss cross pattern along the floor surface Apply the floor cleaner wax evenly over the surface of the floor and add additional floor cleaner wax as needed After the floor cleaner wax has...

Страница 12: ... exterior of the Floor Machine Do not immerse the Floor Machine in liquid When storing make sure to store the Floor Machine in a clean dry safe location out of reach of children and other unauthorized people CAUTION All maintenance service or repairs not mentioned in this manual must only be performed by a qualified service technician TROUBLESHOOTING Problem Possible Cause Possible Solution Machin...

Страница 13: ...A Motor 115 Volt 60 Hz 1 4 Circlip 10 2 5 Flat Washer 10 4 6 Spacer 10 2 7 Wheel 2 8 Motor Shield 1 9 Trademark 1 10 Screw Box 1 11 Handle Screw M8 x 55 1 12 Flat Washer 8 x 16 2 13 Hex Lock Nut M8 1 14 Screw M5 x 18 2 15 Plate 3 16 Locking Pin 1 17 Cord Clip 1 18 P Clip 2 19 Cord Hook 2 20 Pop Rivet Handle 4 4 21 Handle Tube 1 22 Grounding Warning Label 1 23 Screw M5 x 40 2 24 Trademark 1 25 Pad ...

Страница 14: ...Page 14 SKU 94280 For technical questions please call 1 800 444 3353 47A 34A 3A ASSEMBLY DIAGRAM ...

Страница 15: ...ncidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the com plaint...

Отзывы: