Page 10

maintenance and 

serVicing

  Procedures not specifically 

explained in this manual 

must be performed only by a 

qualified technician.

 

to preVent 

serious injurY 

From accidental 

operation: 

turn the power switch of the 

tool to its “oFF” position and 

unplug the tool from its 

electrical outlet before 

performing any inspection, 

maintenance, or cleaning 

procedures.
to preVent serious 

injurY From tool 

Failure: 

do not use damaged 

equipment.  if abnormal noise 

or vibration occurs, have the 

problem corrected before 

further use.

cleaning, maintenance, and 

lubrication

BeFore eacH use,

1. 

 inspect the 

general condition of the tool.  Check 

for loose screws, misalignment or 

binding of moving parts, cracked or 

broken parts, damaged electrical wir-

ing, and any other condition that may 

affect its safe operation.

aFter use,

2. 

 clean external surfaces 

of the tool with clean cloth.

3. 

Warning!  if the supply cord of 

this power tool is damaged, it must 

be replaced only by a qualified 

service technician.

please read tHe FolloWing 

careFullY

THe MANUFACTUReR AND/OR DISTRIBUTOR 

HAs ProViDED THE PArTs LisT AnD 

AssEmBLy DiAgrAm in THis mAnuAL As 

A rEfErEnCE TooL onLy.  nEiTHEr THE 

MANUFACTUReR OR DISTRIBUTOR MAKeS 

ANY RePReSeNTATION OR WARRANTY OF 

ANY KIND TO THe BUYeR THAT He OR SHe 

is quALifiED To mAKE Any rEPAirs To THE 

ProDuCT, or THAT HE or sHE is quALifiED 

To rEPLACE Any PArTs of THE ProDuCT.  

IN FACT, THe MANUFACTUReR AND/OR 

DisTriBuTor ExPrEssLy sTATEs THAT 

ALL rEPAirs AnD PArTs rEPLACEmEnTs 

sHouLD BE unDErTAKEn By CErTifiED 

AnD LiCEnsED TECHniCiAns, AnD noT By 

THE BuyEr.  THE BuyEr AssumEs ALL risK 

AnD LiABiLiTy Arising ouT of His or HEr 

rEPAirs To THE originAL ProDuCT or 

rEPLACEmEnT PArTs THErETo, or Arising 

ouT of His or HEr insTALLATion of 

rEPLACEmEnT PArTs THErETo.

Содержание 66127

Страница 1: ...anual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for...

Страница 2: ...used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury General Power Tool Safety Warnings WARNING Read all safety warnings and instructions Failure to follow th...

Страница 3: ... ensure these are connected and properly used Use of these devices can reduce dust related hazards Only use safety equipment that g has been approved by an appropri ate standards agency Unapproved safety equipment may not provide adequate protection Eye protection must be ANSI approved and breath ing protection must be NIOSH ap proved for the specific hazards in the work area Power tool use and ca...

Страница 4: ...heat is de structive to a Battery Pack The more heat generated the faster the Battery Pack loses power A Battery Pack that gets too hot can be permanently damaged Never over discharge a Battery Pack by using the tool while tool performance is decreasing When tool performance begins to diminish stop the tool recharge the Battery Pack and use the fresh Bat tery Pack for optimal performance Service 5...

Страница 5: ... Fault Circuit Inter rupter GFCI should also be imple mented it prevents sustained elec trical shock Some dust created by power sand 10 ing sawing grinding drilling and other construction activities contains chemicals known to the State of Cali fornia to cause cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from br...

Страница 6: ...aynaud s Disease should not use this tool If you feel any symptoms related to vibration such as tingling numbness and white or blue fingers seek medical advice as soon as pos sible Do not smoke during use Nico 2 tine reduces the blood supply to the hands and fingers increasing the risk of vibration related injury Wear suitable gloves to reduce the 3 vibration effects on the user Use tools with the...

Страница 7: ...y adjustments to the tool Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual Charging the Battery The Battery Pack 15 must be 1 charged for three to five hours before use Do not charge the Battery Pack longer than five hours the Battery Pack and or Charger 21 may be damaged Do not leave the Charger unattended ...

Страница 8: ...g a 2 vise or clamps not included to pre vent movement while working There must not be hazardous ob 3 jects such as utility lines or foreign objects nearby that will present a hazard while working 4 Warning to prevent serious injury verify that the surface has no hidden utility lines before drilling or driving screws General Operating Instructions Mark the position of the hole to be 1 drilled with...

Страница 9: ... illuminated the battery is partially charged If only the red light is illuminated then the battery will need to be charged soon Level Battery Charge Indicator When the hole is drilled remove the 10 drill bit from the hole while the Drill is still running This prevents the Drill Bit from getting caught in the hole and causing damage To prevent accidents turn off the tool 11 and disconnect its powe...

Страница 10: ... condition that may affect its safe operation After Use 2 clean external surfaces of the tool with clean cloth 3 WARNING If the supply cord of this power tool is damaged it must be replaced only by a qualified service technician PLEASE READ THE FOLLOWING CAREFULLY The manufacturer and or distributor has provided the parts list and assembly diagram in this manual as a reference tool only Neither th...

Страница 11: ... 1 Parts List Part Description Qty 12 Connector 1 13 Trigger 1 14 Battery Clamp 1 15 Battery 1 16 Reverse Lever 1 17 Left Body 1 18 Level 1 19 Circuit Board 1 20 Screw 2 21 Charger 1 22 Case not shown 1 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not av...

Страница 12: ...cidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is express ly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the com plaint...

Отзывы: