For technical questions, please call 1-800-444-3353.

8. 

Protect your extension cords from sharp objects, excessive heat, and damp or wet ar-

eas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 OR 240 VOLT)

NAMEPLATE

AMPERES

(at full load)

EXTENSION CORD LENGTH

25 Feet

50 Feet

75 Feet 100 Feet 150 Feet

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

SYMBOLOGY

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute (RPM)

Note:  Performance of this tool may vary depending on variations in local line voltage.  Extension 

cord usage may also affect tool performance.

UNPACKING

When unpacking your Tile Saw make sure that the item is intact and undamaged.  If any 

parts are missing or broken, please call HARBOR FREIGHT TOOLS at 1-800-444-3353.

Содержание 38941

Страница 1: ...site at http www harborfreight com TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE Copyright 1998 2006 by Harbor Freight Tools All rights reserved No portion of...

Страница 2: ...inside of the front cover Write the product s serial number in the back of the manual near the assembly diagram or write month and year of purchase if product has no number Keep this manual and invoi...

Страница 3: ...e the risk of electric shock Only use correct wet cut attachment for wet cutting 4 Do not abuse the Power Cord Never use the Power Cord to carry the tools or pull the Plug from an outlet Keep the Powe...

Страница 4: ...ries or storing the tool Such preventive safety measures reduce the risk of starting the tool accidentally Always unplug the tool from its electrical outlet before performing any inspection maintenanc...

Страница 5: ...e tool is properly grounded A ground fault interrupt GFCI system is also a good precaution This inexpensive device is a good safety measure because it prevents a sustained electrical shock Properly ma...

Страница 6: ...ension cord Using extension cords with inadequately sized wire causes a serious drop in voltage resulting in loss of power and possible tool damage See Table A 3 The smaller the gauge number of the wi...

Страница 7: ...14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 TABLE A Based on limiting the line voltage drop to five volts at 150 of the rated amperes SYMBOLOGY Double Insulated Canadian Standards Association Underwr...

Страница 8: ...F and unplugged 2 A Diamond Cutting Blade is not included with the Tile Saw and must be purchased separately 3 Turn the Tile Saw so that you are looking at the Blade wheel Place the arbor wrench 58 on...

Страница 9: ...43 Brush 2 44 Brush cap 2 45 Cord 1 46 Cord armor 1 47 Base 1 48 Thumb bolt 1 49 Spring washer 1 50 Washer 1 51 Clip 1 52 Water tube 1 53 Elastic pin 6 x 30 1 54 Distance ring 1 55 Thumb bolt 1 56 PV...

Страница 10: ...1 800 444 3353 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only an...

Страница 11: ...en the Thumb Bolt 2 Attach the Water Plug to the Water Tube 52 using the screw 3 Connect the HOSE to the Water Plug 4 Attach the Rubber Connector to the other end of the HOSE and connect to a water su...

Страница 12: ...d tool Care and common sense must be used in planning a safe work area and in finding a safe location for the water bucket described below Gravity Feed Instructions 1 Place a large bucket of water on...

Страница 13: ...ental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCH...

Отзывы: