SKU 08886
PAGE 6
OPERATING INSTRUCTIONS
NOTE: For additional references to the parts listed in the following pages, refer to the
Assembly Diagram (page 12).
Recharging The Power Station’s Battery:
1.
For maximum Battery (part #13) life, the Power Station should be fully charged
at all times.
2.
The time required to fully recharge the Power Station after jump starting an
engine depends on how many jump starts are performed between recharging
sessions. The following Chart shows the approximate recharging times required.
(See Figure A.)
Jump Starts Vs. Recharging Time
Number of
Jump Starts
Recharging Time
(In Hours)
Number of
Jump Starts
Recharging Time
(In Hours)
1
8
4
32
2
16
5
40
3
24
6
48
FIGURE A
3.
Before, during, and after recharging the Batteries (part #13) you may determine
the level at which the Batteries are charged by pressing the red Battery Test
Button (part 5). The Volt Meter (part 4) will indicate the Batteries’ charge status.
(See Figure B.)
RED (POSITIVE)
COPPER BOOSTER CABLE
(#1)
BLACK (NEGATIVE)
COPPER BOOSTER CABLE
(#2)
RED CLAMP
BLACK CLAMP
BATTERY TEST BUTTON (#5)
EMERGENCY LIGHT (#8)
EMERGENCY
LIGHT SWITCH (#6)
VOLT METER (#4)
VOLTAGE SELECT SWITCH (#3)