Maintenance-free Lead Acid battery 

Guidelines for maintenance-free Batteries: 
1. Battery should operate at temperatures between 15°C ~ 50°C. To ensure a longer life span, it 

should be kept between 5°C ~ 35°C. For optimum result, 20°C ~ 25°C will be ideal. When 
temperature falls 15 degrees below zero, battery will undergo some changes in its chemical 
contents and therefore cannot be recharged. Operating the battery at higher temperature will result 
in higher capacity but shorter lifespan, whereas lower temperatures operation has a longer lifespan 
but less capacity. 

2. If the battery is not recharged 72 hrs after it is completely used, it will be permanently damaged.  
3. When the battery is being charged, the internal gases will be electrolyzed into water at the 

negative charge, maintaining the battery’s storage abilities with no water added. However, erosion 
at the charged ends of the battery will cause poor performance.  

4. 

The battery’s cycle lifespan (no. of charge and discharge cycle) is determined by the degree at 
which power is dissipated, especially the degree of discharged each time it is used and the 
recovery charging method. For normal use, the battery can be used for longer hours when less 
power is dissipated each time and vice versa. At 25°C, maintenance-free batteries could be 
charged 150 ~ 200 times at 100% discharge each time.  

5. Decrease in capacity, internal short circuit, deformation in appearance, erosion of charged ends 

and decrease in open circuit voltage are symbols indicating battery is approaching the end of its 
life cycle. 

6. When two batteries are used in parallel connection, the resistance of the cables should be kept 

equal.  

  
Properties of the Lead Acid Battery: 
1. Has no memory effect. Can be charged anytime, even when the recharge indication light is off. 
2. Performance and efficiency are affected by changes in the environment, especially temperature 

and humidity. (Best operated between 20°C ~ 25°C) 

3. Battery discharge naturally according to a certain pattern even not in use. For best performance 

and a prolonged lifespan, it should be recharged every month even when not in use. 

4. Under normal circumstances, battery could last for about a year. 
5. 

When the battery’s life expires, possible indicators include internal short-circuit, decrease in 
capacity, deformation in appearance, erosion of charged ends and decrease in operating voltage.  

  
User’s Precautions: 
1. For first-time use, charge the battery for 10 hrs until it is fully charged. 
2. To maintain performance and lifespan, if product has not been used for 3 months after the initial 

shipment, please fully charge the battery.  

3. 

Before each use, it’s advisable to charge the battery to its full capacity. 

4. The average lifespan of the battery is one year. The user is advised to change the battery after 

one year of use.  

5. The current consumption is in direct ratio with load current. The more current consumption, the 

less the operation time. 

 

 

Содержание FOCUS 515

Страница 1: ...FOCUS 515 Wireless Portable Amplifier System ISO 9001 2008 TAIWAN EXCELLENCE TAIWAN GOOD DESIGN GREEN PRODUCT Operation manual...

Страница 2: ...nctions Configuration Focus 515 comes equipped with the following 1 A switch mode power supply 2 One wireless microphone except non wireless versions Optional accessories 1 Carrying bag 2 Tripod stand...

Страница 3: ...DC end of the switch mode power supply into the DC IN of the unit and charging will start automatically The charging indicator LED flashes GREEN during the charging process When GREEN LED stays glowi...

Страница 4: ...nd hold to fast forward 5 Press to record 6 Press to switch repeat modes 7 Press to stop playing or recording 8 IR sensor area 9 USB 2 0 input 10 USB SD indicator The LED flashes green during playing...

Страница 5: ...d slide the batteries into the battery compartment replace the battery cover Note Batteries contain a corrosive acid that may leak and damage the microphone when stored for a long period Batteries sho...

Страница 6: ...acid that may leak and damage the belt pack when stored for a long period Batteries should be removed from the belt pack before storing without use for more than 4 weeks When the transmitter is switch...

Страница 7: ...Decrease in capacity internal short circuit deformation in appearance erosion of charged ends and decrease in open circuit voltage are symbols indicating battery is approaching the end of its life cy...

Страница 8: ...chiayo com tw Email sales chiayo com tw Office 30 Lane 27 Section 4 Jen Ai Road Taipei 10685 Taiwan Tel 886 2 27415741 Fax 886 2 27525242 Factory 88 Chung Hsiao Street 2 Chiayi 60080 Taiwan Tel 886 5...

Отзывы: