6
Instructions
Setting microphone
’s sensitivity from the receiver
1
Press
SET
button to make the sensitivity level flashes
→
2
Press DOWN(
▼
) and UP(
▲
) button to adjust the sensitivity level between -1, 0 and 1.
3
After a level is chosen, wait about 5 seconds to save the setting and the level will not
change after reboot until the setting is changed again.
1.
Setting the sensitivity of
HANDHELD MICROPHONE
Sensitivity value
-1
0
1
Dynamic range
high
middle
low
Noise & feedback
low
middle
high
Mic cartridge to mouth
< 5 cm
5 cm to 10 cm
> 10 cm
Suggested applications
singing or talking when holding
the microphone
Speech with microphone
mounted on tripod stand
2.
Setting the sensitivity of the
LAVALIER
and
HEADSET
MICROPHONE
of the beltpack
transmitter
Sensitivity value
-1
0
1
Dynamic range
high
middle
low
Noise & feedback
low
middle
high
Mic cartridge to mouth
< 10 cm
10 cm to 20 cm
> 20 cm
3.
Setting the sensitivity of
INSTRUMENT
input of the beltpack transmitter
Sensitivity value
-1
0
1
When to choose
Instrument input
level too high
default
Instrument input
level too low
Function
Decrease input level
default
Increase input level
Important:
◼
The farther distance from mouth the higher sensitivity is required. The default gain level is
0
.
◼
Higher sensitivity will lower the dynamic range of input signals, which may result in more
feedback concern.
◼
Above description is for reference only. Please set the sensitivity at a proper level when
operating the microphone system.