![CHIAROSCURO SLIDE.80 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/chiaroscuro/slide-80/slide-80_use-and-installation-manual_2597882012.webp)
SLIDE.80
110-230Vac / 24Vdc
Cod.
151116
CHIAROSCURO SAS di Girelli Marco & C.
C.So General A.Cantore 23 - 38061 Ala (TN) Italy
P.I. IT01527050221
Pag. 12di 16
7.5
ELECTRICAL
CONNECTIONS
This work has to be done by a qualified Electromechanical Dealer. CHIAROSCURO SAS doesn’t have
responsibilities in the case of bad installation and/or mistakes made by not qualified operators.
7.5.1
Electrical Scheme
2
ORDINANCE 22 January 2008 - , n. 37 Rule in reference to the execution of the article 11-quaterdecies, subparagraph
13, letter a) of thr law n. 248 of 2 December 2005, describing reorgasnization of disposal about installation activities of
implants inside the buildings.
The proper functioning of device and the safety requirements are guaranteed only if it’s connected to
certified electrical system that respect the applicable laws (in Italy DLgs. 37/2008
2
).
The producer doesn’t have responsibilities for any damage to the device or at other people caused by
the use of a non-compliant electrical system, or caused by an electrical system that doesn’t respect the
applicable laws .
If the device behavior doesn’t reflect what is reported above, don’t use the automation and contact the
Customer Care service of CHIAROSCURO SAS. It’s hardly forbidden to open the case of the device
except written authorizations of CHIAROSCURO SAS. Not respecting this rule will cause the
immediately decay of warranty.
The predisposition of the electrical system is responsibility if the electromechanical dealer.
CHIAROSCURO SAS doesn’t have the responsibility for system lacks. All the information to make a
good work are at disposal, it’s a buyer burden request it in a formal way.
Version 110 ÷ 230Vac
Motor cable
Description
Brown
Line 110-230 Vac
Blue
Neutral / Common
White
Key 1 rot.clockwise
Red
Key 2 rot.anticlockwise
Program
Contact
Automatic
N.O. impulsive 1sec.
Dead man
N.O.
Version 24Vdc
Motor cable
Description
Red
+ 24 Vdc
White
-24 Vdc / Common
Cable 1
Key1 rot. clockwise
Cable 2
Key2 rot. anticlockwise
Program
Contact
Automatic
N.O. impulse 1sec.
Dead man
N.O.