1. Install the IMT valve actuator valve to the IMT valve.
Caution:
Refer to
Fastener Caution
in the Preface section.
2. Install the IMT valve actuator valve bolts.
Tighten
Tighten the IMT valve actuator valve retaining bolts to 12 N·m (106 lb ft).
3. Connect the vacuum hose to the IMT valve actuator valve.