CONNECT MODE

 – To enable Connect Mode, use the drop down menu and select DISABLED for 

Mode. Connections to designated Host IP Address will be initiated and held upon device power up. Under 
Host 1, enter the target IP Address, Port Number, and Protocol (TCP or UDP). The Local Host Port 
Number does not need to be specified as it is randomly generated.  

If using UDP Broadcasts, enter in the local network broadcast address (ends in 255). For example on the 
Private IP Network of 192.168.0.0 the broadcast address would be 192.168.0.255. UDP packets will then be 
sent to all devices on the local network. Each listening device must be set to ACCEPT on their own IP 
address. 

 

 

Connect Mode – UDP Broadcast – Data is sent to all 
devices on the subnet using the specified port number. 
Each receiving device must be set to listen on its on 
interface IP address. Allows multiple devices to receive 
the same SeaSmart.net transmissions 

Connect Mode – Web Server Post – Setting the 
protocol to TCP and Port number to 80 will enable 
SeaSmart.net to POST data directly to a local Web 
Server running ASP. The live data can then be logged 
and viewed with any Browser. 

 

Содержание SeaSmart.Net

Страница 1: ...SeaSmart Net Version 1 3 0 Gateway Adapter Chetco Digital Instruments Preliminary Specification 041212...

Страница 2: ...storage temperatures higher or lower than specified will cause the liquid crystal display to fail Neither this type of failure nor its consequences are covered by the warranty For more information con...

Страница 3: ...d can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interfe...

Страница 4: ...date 127493 Transmission Data Dynamic Update 127497 Trip Parameters Dynamic Update 127505 Fluid Data Dynamic Update 127508 Battery Status Dynamic Update 127506 DC Status Detail 127513 DC Config Detail...

Страница 5: ...Update System 21 Port Mode 23 ACCEPT MODE 23 CONNECT MODE 25 PACKING MODE 26 WLAN Profiles 28 FTP File Update 31 FTP Firmware Update 37 XML Config 42 Quick Syntax Tour for XCRs 42 Record Group Item an...

Страница 6: ...SeaSmart Net Adapter Manual Version1 3 6...

Страница 7: ...ectional communications between networks SeaSmart Net adapters are available for NMEA 0183 to Ethernet 10 100 with Embedded Web Server NMEA 0183 to WiFi 802 11 b g with Embedded Web Server NMEA 2000 t...

Страница 8: ...a to serial data and then to 10 100 Ethernet RJ45 SeaSmart Net Protocol translator passes data to embedded Web Server which is accessed over Ethernet Infrastructure networks using Web Browser compatib...

Страница 9: ...s translated and passed on to both the target network and embedded Web Server Listeners on the Ethernet WiFi networks can use both TCP and UDP protocols to access the data SeaSmart Net adapters are co...

Страница 10: ...supplied Micro C adapter cable to connect to a NMEA 2000 bus T connector SeaSmart Net uses Opto isolators and thus is power and ground isolated from the NMEA 2000 network SeaSmart Net adapters only d...

Страница 11: ...to the assigned address which is described in the following section Web Brower Interface The simplest way to use SeaSmart Net adapters is with the embedded Web Interface Data from the connected NMEA n...

Страница 12: ...00 Engine SeaSmart Net Web Page for NMEA 2000 Weather Single Dials use a single PGN Instance and Dual Dials use two different instances Engine data use PGN127488 127489 127493 127501 127505 127508 130...

Страница 13: ...a Detailed Engine Data Single Instance Detailed Engine Data Single Instance Basic Dual Engine Data Detailed Battery Info Single Instance Detailed Fuel consumption and Tank Level Data Logging Tool Bar...

Страница 14: ...c Text White Classic Text Black Classic Dial White Classic Dial Black Garmin style Dials Instance Tool Bar The Instance Tool bar selects the PGN Instance to display many PGNs engine data for example w...

Страница 15: ...Normal access is via translated NMEA 2000 data using the SeaSmart Protocol This allows sharing of NMEA 2000 data with multiple Applications by selecting different port number SeaSmart can support mult...

Страница 16: ...ork monitoring tools or Router Interface tools may be used to determine the local address assigned One such tool is the Lantronix Device Installer 4 0 2 supplied on the SeaSmart Net application CD or...

Страница 17: ...SeaSmart Net Adapter Manual Version1 3 17 Selecting the ADAPTER SETUP link will navigate to the SeaSmart Configuration page were various set up and maintenance operations can be performed...

Страница 18: ...Memory used to assign a static IP address or enable DHCP for dynamic IP address Also used to change device host name Used to upload new device firmware files or reboot Used to configure access to seri...

Страница 19: ...ay format Web View SINGLE Engine NMEA 2000 SeaGauge Remote Sensor Units use a NMEA 0183 type of protocol IIXDR Therefore select the appropriate Icon when displaying data from a directly connected SeaG...

Страница 20: ...or replace a existing file is the same First select the appropriate directory before selecting a local file The Folder Icons underneath the File system Browser Banner will expand or contract subdirec...

Страница 21: ...ct the CONFIGURATION link The configuration page will allow enable or disable DHCP Client If DHCP Client is enabled then no IP address is required as it will be automatically generated If DHCP Client...

Страница 22: ...rt Net device The process to update Firmware is to first select the desired file on the local PC and then to Upload transfer to the adapter After the transfer is complete the adapter will reboot Firmw...

Страница 23: ...nable Accept Mode change the Drop Down to Disabled This will ensure that connections are always made regardless of live data at the interface Other options allow connections to only be accepted when n...

Страница 24: ...r determines the operational mode for TUNNEL 1 with 10001 being the default mode and TUNNEL 2 set to DISABLED In this mode only one TCP port number will be able to ACCEPT incoming connections If TUNNE...

Страница 25: ...Private IP Network of 192 168 0 0 the broadcast address would be 192 168 0 255 UDP packets will then be sent to all devices on the local network Each listening device must be set to ACCEPT on their o...

Страница 26: ...FFER NOT CLEARED The Tunnel Packing parameters control how data is retrieved using HTTP Get Requests GETNMEAData Packing Mode determines if data is packed before transmission in response to a HTTP GET...

Страница 27: ...ata Threshold Specifies the amount of data in terms of Bytes value 10 to return in response to a HTTP GET request Data is held in the internal buffer till it exceeds the Threshold value and then it is...

Страница 28: ...i device and Host PC Uses Auto Config IP address and no DHCP server Only requires a single host device PC Smart Phone NetBook to create a connection This sort of network is suitable for direct link be...

Страница 29: ...re tried in order until a successful connection is made List of Profiles to be tried in order on Boot The default is to start with a Ad Hoc Profile SeaSmart Ad Hoc since it is usually the simplest to...

Страница 30: ...p Page Select NETWORK 2 for Wireless Status List of Profiles to try on Boot up Always leave a Ad Hoc profile in the list so that recovery can be performed in case a listed network becomes unavailable...

Страница 31: ...the content of the Web Server it is usually easier to use FTP Most Browsers including Internet explorer include FTP upload support This example uses the native FTP services built in to Windows Vista a...

Страница 32: ...SeaSmart Net Adapter Manual Version1 3 32 Allow the Site to be Open in Explorer Enter username admin and password seasmart...

Страница 33: ...SeaSmart Net Adapter Manual Version1 3 33 The Http directory contains all of the Web Content To Delete the existing Directory Right Click and choose Delete...

Страница 34: ...SeaSmart Net Adapter Manual Version1 3 34 Confirm the Delete Http Directory Directory is removed from adapter Prepare to copy new Http directory from SeaSmart update folder...

Страница 35: ...SeaSmart Net Adapter Manual Version1 3 35 Right Click and select COPY from update folder In FTP directory Right Click and select PASTE File Copy Status...

Страница 36: ...iewing contents of directories and checking number of files in each sub directory with source Occasionally some files may not be copied due to Flash Compaction timeout If this occurs repeat the upload...

Страница 37: ...rectory and the device rebooted Upon reboot the new firmware will be load into operational Flash memory and uploaded file deleted The Firmware update should be performed after new Web Content is uploa...

Страница 38: ...SeaSmart Net Adapter Manual Version1 3 38 The file will be uploaded to the SeaSmart adapter root directory The new firmware will not be loaded until the device is rebooted or power cycled...

Страница 39: ...SeaSmart Net Adapter Manual Version1 3 39 To reboot go to the main SeaSmart Web page and select Adapter Setup Then select SYSTEM...

Страница 40: ...SeaSmart Net Adapter Manual Version1 3 40 Select REBOOT While restarting the new Firmware file will be copied to operational FLASH memory and the old file deleted...

Страница 41: ...SeaSmart Net Adapter Manual Version1 3 41 After Reboot the main SeaSmart Web Page should appear...

Страница 42: ...AME FOR EACH CONFIGGROUP SPECIFIED WITH THE NAME ATTRIBUTE IS THE GROUP NAME LISTED IN THE WEB MANAGER XCR GROUPS AN EMPTY OR MISSING VALUE ELEMENT IN EACH PRESENT CONFIGGROUP CLEARS THE SETTING TO IT...

Страница 43: ...d must contain one or more configitem elements It must have a name attribute and may have an instance attribute A configitem is a specific grouping of configuration parameters relevant to its parent g...

Страница 44: ...value name private key value configitem configgroup Figure 4 5 XML Example with Multiple Items xml version 1 0 standalone yes configgroup name email instance 1 configitem name to value john doe somewh...

Страница 45: ...in the XCR This can be done on any level including the root Special tags in the XML allow for providing root and enable level passwords so that this can also be done at the password prompt Web browse...

Страница 46: ...Adapter Manual Version1 3 46 WEB INSTALL OF SEASMART XML FILE SELECT THE XML LINK FROM THE FULL CONFIG TAB SELECT IMPORT CONFIGURATION SELECT BROWSE TO CHOOSE THE FILE TO IMPORT PICK A SEASMART XML FI...

Страница 47: ...Net Adapter Manual Version1 3 47 CLICK THE IMPORT BUTTON SELECT OK ON THE STATUS DIALOG AFTER IMPORT REBOOT REPOWER THE DEVICE TO APPLY CHANGES A NEW SEASMART XML FILE WILL BE CREATED IN THE CONFIG D...

Страница 48: ...Net Adapter Manual Version1 3 48 SeaSmart XML The SeaSmart XML file is stored in the Config directory The file is automatically generated from the current configuration upon each boot repower of the...

Страница 49: ...apter Manual Version1 3 49 The contents of the SeaSmart xml file can be read to determine the current operational mode of the adapter The SeaSmart xml file can also be modified and reloaded to alter d...

Страница 50: ...contains the following Config Items Accept Mode This value is always set to DISABLE to allow the SeaSmart adapter to override the native protocol translator and utilize the PCDIN protocol Local Port...

Страница 51: ...ata Threshold Specifies the amount of data in terms of Bytes value 10 to return in response to a HTTP GET request Data is held in the internal buffer till it exceeds the Threshold value and then it is...

Страница 52: ...Net Adapter Manual Version1 3 52 Full Config Advanced configuration options can be accessed from the Full Config Web Page Please consult the XPORT_PRO_USERS_GUIDE for further information on advanced...

Страница 53: ...ico C drop cable 1 dot Blue N 2 Red 12V 25 mA max 3 Black Ground 4 White N Serial USB Conxall 8 pin to USB or Conxall 8 Pin to Conxall 8 pin Serial RS232 1 dot No Connect 2 TX RS232 3 USB 4 5 V input...

Страница 54: ...SeaSmart Net Adapter Manual Version1 3 54...

Страница 55: ...SeaSmart Net Adapter Manual Version1 3 55 Dimensions...

Страница 56: ...SeaSmart Net Adapter Manual Version1 3 56...

Страница 57: ...REFUND AS JUST DESCRIBED IS THE EXCLUSIVE REMEDY AVAILABLE TO YOU AGAINST US FOR ANY DEFECT MALFUNCTION OR NON CONFORMITY CONCERNING THE PRODUCT OR FOR ANY LOSS OR DAMAGE RESULTING FROM ANY OTHER CAUS...

Страница 58: ...reserve the right to terminate this license if you violate any aspect of this License Agreement 3 The SOFTWARE housed in your product are protected by the copyright notices appearing on the product o...

Страница 59: ...day except holidays Your unit is covered by a full one year warranty See inside for complete warranty details If your unit fails and the failure is not covered by the original warranty Chetco Digital...

Отзывы: