SeaSmart.Net Adapter Manual Version1.3
24
SeaSmart.net adapters support several types of Accept modes. When both TUNNEL ACCEPT Modes are
set to Disabled (default), data from one or both ports (NMEA 2000 or Serial) is passed-through (Tunneled)
to the pre-selected TCP port (TUNNEL 1) using the following rules.
•
TCP PORT 10001 – Translated NGT NMEA 2000 data to SeaSmart.net Protocol
•
TCP PORT 10002 – Serial Data from External RS232 connector
•
TCP PORT 10003 – Combined SeaSmart.net NMEA 2000 data and External Serial (RS232) data
•
TCP PORT 10004 – RAW un-translated NGT NMEA 2000 data
The setting of the Port number determines the operational mode for TUNNEL 1 with 10001 being the
default mode and TUNNEL 2 set to DISABLED. In this mode, only one TCP port number will be able to
ACCEPT incoming connections.
If TUNNEL 2 is set to ENABLED, serial (RS232) data from the external connector is passed through
(Tunneled) to the specified Port. This allows a second TCP port to also ACCEPT incoming connections
and supply NMEA 0183 or AIS data over an independent link from NMEA 2000 data.
TUNNEL 1
TUNNEL 2
MODE
DISABLED
DISABLED
ACCEPT TUNNEL 1 ONLY (Ports 1, 2 or Both)
10001 = SeaSmart NMEA 2000 data
10002 = External Serial Data (NMEA 0183)
10003 = Combined SeaSmart and Serial data
10004 = RAW NGT NMEA 2000 data
DISABLED
ENABLED
ACCEPT TUNNEL 1 and 2 (Port 1 and Port 2)
ENABLED DISABLED NOT
ALLOWED
ENABLED ENABLED NOT
ALLOWED
Содержание SeaSmart.Net
Страница 1: ...SeaSmart Net Version 1 3 0 Gateway Adapter Chetco Digital Instruments Preliminary Specification 041212...
Страница 6: ...SeaSmart Net Adapter Manual Version1 3 6...
Страница 41: ...SeaSmart Net Adapter Manual Version1 3 41 After Reboot the main SeaSmart Web Page should appear...
Страница 54: ...SeaSmart Net Adapter Manual Version1 3 54...
Страница 55: ...SeaSmart Net Adapter Manual Version1 3 55 Dimensions...
Страница 56: ...SeaSmart Net Adapter Manual Version1 3 56...