SEAL MAINTENANCE AND REPAIR cont.
26
Flip the gland and Insert the stationary seal
face into the gland (as shown), carefully
aligning the drive slots with the lugs in the
gland. Press evenly on the face to ensure that
the seal face is fully seated. Clean the face
surface with a clean cloth.
25
Wrap threads of pipe plug 1 ½ wraps with
Chesterton GoldEnd
™
tape (or equivalent)
Insert pipe plugs (2X) into gland and tighten to
recommended torque value.
Slide the lock ring over the sleeve. Align dog
point screw holes in the lock ring with holes in
the sleeve. Tighten dog point screws until flush
with inside diameter of sleeve.
29
Tighten centering clip hex screws.
31
30
Press down on gland assembly and rotate
centering clips to engage under the lock ring.
24
Insert shoulder screws with washers into
springs and install in pusher holes. Tighten
shoulder screws evenly in a crisscross pattern
and until they bottom out.
Flip the gland assembly and carefully slide the
gland over the sleeve until the seal faces are
mated.
Install dog point and TORX screws into lock
ring.
Insert hex head screws into centering clips;
insert into the bushings and tighten finger-tight.
Install bushings in 4 large through holes.
Align through holes in pusher with threaded
holes in gland.
NOTE
(not applicable for all
sizes): Align scalloped edge of pusher with NPT
flush port in gland as shown in inset.
23
22
21
27
28
32
Install eye bolts for ease of transportation.
IMPORTANT:
Remove eye bolts prior to seal
installation.