16
LIMIT SWITCH SETTING
The motor can learn the limit switches only in manual mode.
It is suggested that the strength of the awning, its couplings and its safety lugs be checked.
As long as both of the limit switch positions have not been learned, the motor
will move briefly, stop and then start back up again.
PROCEDURE FOR LIMIT SWITCH SETTING
Depending on your individual needs, it’s possible to learn first either the upper or the
lower limit switch.
EXAMPLE 1:
SETTING THE UPPER LIMIT SWITCH AS FIRST POSITION
If the awning is already completely closed up, it must be first opened out to
about 20 cm, then proceed as follows.
Using the button switch, bring the awning up to the desired position (for cassette-
awnings, hold the button pressed until the motor stops automatically on the closing
position).
To set the upper limit switch position perform the indicated sequence of commands
(UP-UP-UP) with the button to be linked to the ascent.
Using the button to be linked to descent bring the awning down to the desired position.
To set the lower limit switch position perform the indicated sequence of commands
(DOWN-DOWN-DOWN).
UP
UP
HOLD
UP
2 sec
DOWN
DOWN
DOWN
HOLD
2 sec
DOWN
UP
?
DOWN
UP
?
E
NG
L
IS
H
Содержание Wave Wire