MAGO Switch and MAGO Control Unit advanced settings menu
37
Parameter
Options
Description
Motor type
Standard (default)
For motors with a mechanical/electronic
limit switch with standard connection
(brown, black, blue). The outputs will
remain active throughout the travel (up/
down travel time).
Pulses
For motors with white wire control. The
outputs are managed by pulses.
Motor for adjustable
shutter with
connector
No (default)
Mode 5
Yes
Mode 4
Venetian blind
control mode
CH Cherubini (default) Short pulse <1 sec: Impulsive
Long pulse >1 sec: Continuous motion
EU European
Short pulse <2 sec: Impulsive
Long pulse >2 sec: Continuous motion
US United States
Short pulse >0,5 sec: Impulsive
Long pulse <0,5 sec: Continuous motion
Specialisation
Rolling shutter
The specialisation is indicated during the
creation of the system and can be changed
from this menu.
Awning
Screen
Venetian blind
Orientable shutter
Upward travel
time
0-240 seconds
(default 30)
Output activation time during the
motor raising movement
Downward travel
time
0-240 seconds
(default 30)
Output activation time during the
motor lowering movement
Position adjustment
time
10-100 tenths of a
second (default 10)
Total slat tilting time
Preferred position 1 0-100%
(default 25%)
Preferred intermediate position 1
Preferred position 2 0-100%
(default 75%)
Preferred intermediate position 2