SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily,
for example, with the purpose of setting the limit switches during
assembly in the factory. A later final saving of the remote control will
be possible using the appropriate command sequence (see: “SETTING
THE FIRST REMOTE CONTROL”).
The operations described below can be carried out only when the
control unit has just come out of the factory or after a full memory
clearing (see: “FULL MEMORY CLEARING”).
The control unit makes the following operations possible only within
the time limits described in order to make sure that the short-term
setting is used only in the installation or factory setting phase and not
during daily use. Power up the control unit, make sure that no other
control units having an empty memory are powered up in the same
operating range.
Within 30 seconds after start,
press the B and C buttons
simultaneously until the motor gives a confirmation signal.
The remote control will remain stored for 5 minutes,
while the
control unit is powered up. After 5 minutes or when the control unit
has its power cut off, the remote control will be cancelled.
T1: First remote control to be stored
24
GB
T1
CHERUBINI S.p.A. declares that the product is in conformity with
the relevant Union harmonisation legislation:
Directive 2014/53/EU, Directive 2011/65/EU.
The full text of the EU declaration of conformity is available upon
request at the following website: www.cherubini.it.
EU DECLARATION OF CONFORMITY