Страница 3: ...ening distance of the contacts of at least 3 mm before the circuit The MyRoll control unit was explicitly designed to be installed in a junction box or socket boxes Is not waterproof and has a ligh impact protection Do not instal the control unit without adequate protections Do not open or perforate the control unit box ELECTRICAL CONNECTIONS 14 L1 N C L1 N 2 switches optional control M 1 Browm 2 ...

Страница 4: ...sor is ON GIRO P Lux DISPLAY Change channel Activating Deactivating the Sun sensor Wind sensor is ON Sun sensor is ON To prevent accidental changes to the programming of the motor during the daily use of the remote control the possibility of programming is disabled automatically 8 hours after sending the last sequence A B or B C display Activating Deactivating the Sun sensor Channel selector LED C...

Страница 5: ... rotation DOWN UP Press button A Press buttons A and B at the same time TECHNICAL FEATURES Power supply 230 V 50 Hz Radio frequency 433 92 MHz Decoder system Rolling code Modulation AM ASK Max number storable transmitters 15 Max motor power 500 W Operating temperature 10 C 55 C Dimensions 48 5 x 48 5 x 22 mm Weight 30 g 16 GB DOWN UP ...

Страница 6: ...ds are taken the command is not accepted and the sequence must be repeated Command sequence example As we can see from the example when the sequence ends positively the motor returns to its starting position in one long rotation In fact two short rotations in the same direction correspond to one long rotation in the opposite direction The motor returns to the starting position even when the sequen...

Страница 7: ...t match to the UP and DOWN functions of the remote control as an exemple when giving the ascent command the rolling shutter awning descends Setting the rotation direction using the button RESET AUX The rotation direction can be reversed also by interchanging the BROWN motor wire with the BLACK motor wire The control unit will keep this setting even after complete memory clearing SETTING OF ADDITIO...

Страница 8: ...estored The same applies to the single channels of a multichannel remote control just select the channel to cancel Tn Remote control to be cleared Tn Tn Tn 2 sec FULL MEMORY CLEARING The full memory clearing can be performed in two ways 1 WITH THE REMOTE CONTROL Tn Already programmed remote control I Tn 4 sec 2 WITH THE BUTTON RESET AUX Tn Tn 19 GB 8 sec RESET AUX ...

Страница 9: ...clearing SWITCH It is possible to run the motor through a switch connected to the control unit with a wire Optional switch The switch must be equipped with mechanical or electrical interlock to prevent two commands being sent simultaneously Furthermore the switch must be an unstable pushbutton releasing it the switch opens 20 GB OPERATION Pressing one of the two buttons and releasing the motor dri...

Страница 10: ... sequence set 2 sec SELECTOR LED SET BUTTON MISTRAL cod A520012 NB During the wind alarm the led inside the MyRoll blinks I For the complete description of the functions of this device see the instruction booklet that came in the box DELETING THE SENSOR To delete the sensor from the control unit an already programmed remote control must be used Set the sensor selector to the 0 position if active w...

Страница 11: ...n of the functions of these devices see the instruction booklet that came in the box SETTING To associate the sensor to the control unit a remote control must be already memorised The setting sequence is the following DELETING To delete the sensor from the control unit an already programmed remote control must be used The deleting sequence is the following set 2 sec set 2 sec NB During the wind al...

Страница 12: ... waiting for activation times After 3 minutes the WindTec sensor returns to normal operational mode During the test mode the led inside the MyRoll is on WIND FUNCTION TEST WINDTEC WINDTEC LUX To avoid errors during the wind function test it is suggested that the sunlight function be deactivated By spinning the anemometer fins when the speed detected by the sensor exceeds the threshold set the moto...

Страница 13: ...d only in the installation or factory setting phase and not during daily use Power up the control unit make sure that no other control units having an empty memory are powered up in the same operating range Within 30 seconds after start press the B and C buttons simultaneously until the motor gives a confirmation signal The remote control will remain stored for 5 minutes while the control unit is ...

Страница 14: ......

Страница 15: ......

Страница 16: ...ère 30600 Vauvert France Tél 33 0 466 77 88 58 Fax 33 0 466 77 92 32 info cherubini fr www cherubini fr CHERUBINI Iberia S L Avda Unión Europea 11 H Apdo 283 P I El Castillo 03630 Sax Alicante Spain Tel 34 0 966 967 504 Fax 34 0 966 967 505 info cherubini es www cherubini es CHERUBINI S p A Via Adige 55 25081 Bedizzole BS Italy Tel 39 030 6872 039 Fax 39 030 6872 040 info cherubini it www cherubin...