WIND SENSOR WINDTEC SC
This kind of Wind-sensor must be wired to the control unit on the indicated terminals,
without respecting the polarity. Exceeding the set level the control unit will automatically
perform the command associated to UP ward function of the remote control. So check
that the rotation direction will correctly match this function. If not it’s absolutely
necessary to set the rotation direction. The “Wind-alarm” time is 8 minutes during which
the control unit will not accept any command. During the wind-alarm the red led inside
the control unit blinks.
WIND-SPEED SETTING
(WINDTEC SC)
In factory set on:
25 km/h
The control unit will keep the wind-speed setting
even after complete memory clearing!!
36
E
NG
L
IS
H
WARNING:
do not connect more than 5
control units to one anemometer
WindTec SC.
WINDTEC SC - Ref. A520010
2 sec
25 km/h
15 km/h
35 km/h
+
B
C
A
C
B
B