S423/C/OPT Optical oxygen probe – Data Sheet 

15 

 
 

 

TECHNICAL DATA 

DIMENSIONS 

Materials

 : 

  AISI 316 Body (PVC Body optional) 

  Special Glass Optics 

  NBR and Sylicon O-Rings 

 

 

Thread: 

3/4” BSP 

Measuring ranges:

 0,00 to 20,00 mg/L 0-200% 

Measuring method: 

Optical measure by 

luminescence 

Accuracy:

 +/-0,1mg/L or +/-1 % 

Response: 

90% of the value in less than 60 

seconds

 

Maximum refreshing time: 

< 1 second

 

WorkingTemperature:

 -10

÷

60 °C 

Max Working Pressure:

 5 bar 

Maximum absorption:

 2W

 

Mechanical Protection:

 IP68 cable  

Cable:

 10m integral

 

Power Supply:

 12…24Vdc 

Signal interface:  

RS-485 Modbus RTU Protocol

 

Water move:  

No necessary move

 

Compensation of temperature:  

Via internal NTC

 

Luminophore diameter: 

10mm

  

Connector IP67: 

yes

 

 

Order codes

 

        

 

 
 

9700830067 

S423/C/OPT 

 

Optical Oxygen and Temperature Probe 

9700831067 

S423/C/OPT PVC Optical Oxygen and Temperature Probe 

9700832067 

S423/C/OPT 4-20mA Optical Oxygen and Temperature Probe 

9700833067 

S423/C/OPT 4-20mA PVC Optical Oxygen and Temperature Probe 

9400410134 

Luminescent membrane with AISI316 support for S423/C/OPT 

9400410135 

Luminescent membrane with PVC support for S423/C/OPT 

CHEMITEC s.r.l. 
Via Isaac Newton 28 - 50018 Scandicci (FI) 
Tel. +39 055 7576801 fax +39 055 756697 
Web site: www.chemitec.it  
E-mail: [email protected]

 

Содержание S423/C/OPT

Страница 1: ...S423 C OPT SONDA OSSIGENO OTTICA OPTICAL OXYGEN PROBE MANUALE TECNICO TECHNICAL MANUAL P N Rev 0 Ver 1 0 EDIZIONE Febbraio 2014 EDITION February 2014...

Страница 2: ...ity to set salinity and barometric pressure for the compensation of the oxygen value Operating principle A relation exists between the oxygen concentration in the sample and the luminescence intensity...

Страница 3: ...e intensity in absence of oxygen Luminescence decay time in presence of oxygen 0 Luminescence decay time in absence of oxygen KSV Stern Volmer constant quantifies the quenching efficiency and therefor...

Страница 4: ...nstructions Electric installation Turn off the instrument connect the cables of the probe to the terminal block of the meter Please observe the colors shown on the sticker located under the electronic...

Страница 5: ...7connector for the connection to the 42 and 50 series units and can be provided with the appropriate probe holder S315 O available in various tube lengths Together with the probe holder is provided a...

Страница 6: ...the probe periodically The frequency of this operation will be determined by the user taking into account the type of application and the type of electrode used NOTE To perform a calibration in oxygen...

Страница 7: ...ss containing the polymer see figure below Furthermore it is necessary to pay particular attention to the substances with which the part of the probe deputed to measurement can come into contact for e...

Страница 8: ...tection IP68 Sensor cable Cable 10m integral Power Supply 12 24Vdc Signal interface RS 485 Modbus RTU Protocol Water move No necessary move Compensation of temperature Via internal NTC Luminophore dia...

Отзывы: