CG-1978-P, CG-1979-P and CG-3498 Probes for Reactor Systems Installed in Hazardous/XP or ATEX 

environments. 

 

Chemglass PT100 and thermocouple probes that will be used in a hazardous/explosion proof area 

must be used with a Zener barrier. 

 

Zener barriers are used in control and instrumentation systems for the process of standardized 

signals, such as 20 mA or 10 V. Zener barriers contain intrinsically safe circuits that are to be used to 

drive intrinsically safe field devices with hazardous area. The manufacturer’s data sheets must be 

consulted. The relevant regulations and directives governing the intended application must be 

followed. Zener barriers must be installed in conformance with the National Electrical Code. Please 

check with your company/university. 

 

 

 

 
 
 
 
 
 
 
 
 

 
 
 

 

 

 

3800 North Mill Road, Vineland, NJ 08360 

US & Canada Phone: (800) 843-1794     International: (856) 696-0014 

US & Canada Fax: (800) 922-4361     International: (856) 696-9102 

PT100 Sensor in 

Reactor System 

Содержание CG-1959-U1000

Страница 1: ...8360 Phone 800 843 1794 Fax 800 922 4361 ASSEMBLY INSTRUCTIONS FOR UNJACKETED BENCHTOP FILTER REACTOR SYSTEMS Support Frame with Oversized Rugged S S Uprights and Heavy Duty PTFE Coated Aluminum Fitti...

Страница 2: ...om the wood crates in case you need to return items for repair or replacement Crate 1 Unpack the support frame with reactor and components by removing the plastic electrical ties that hold the reactor...

Страница 3: ...0 Small Kwik Klamp II 1ea CG 3498 03 90 Support Rod 1 The support frame has a universal motor mount It can be used with an vertical or horizontal electric air or optional explosion proof XP motor The...

Страница 4: ...embly CG 2095 slides over the end of the shaft The height from the bottom will depend on the total volume you intend to run in the reactor 3 Once you have the upper agitator in place tighten the compr...

Страница 5: ...it is pushed down on all edges evenly 5 Wrap the lower outlet adapters with NPT end with PTFE tape Thread the adapter into the filter base until it becomes snug DO NOT OVER TIGHTEN 6 Attach the beade...

Страница 6: ...vessel lid onto the vessel carefully insert the end of the stirrer shaft through the 45 50 center neck of the lid PLEASE NOTE THE MECHANICAL SEAL STIRRER BEARING IS NOT INSERTED IN THE HEAD AT THIS TI...

Страница 7: ...www cglifesciences com technical service cglifesciences com...

Страница 8: ...www cglifesciences com technical service cglifesciences com...

Страница 9: ...uch as 20 mA or 10 V Zener barriers contain intrinsically safe circuits that are to be used to drive intrinsically safe field devices with hazardous area The manufacturer s data sheets must be consult...

Отзывы: