PART 4
THINGS TO DO BEFORE CALLING THE AUTHORISED SERVICE
If the red temperature warning light is lit continuously (it means the
inner temperature is too high.)
;
• Check whether the lid is closed properly,
• Check whether your chest freezer is in the vicinity of any heating
source,
• Check whether there is a thick frost layer on the inner wall,
• Check whether the ventilation grid is clear.
If the compressor is running on continuously;
• Check whether the ambient temperature is over +43°C,
• Check whether the lid is opened quite frequently,
• Check whether thermostat knob is set to a cooler position more
than adequate,
• Check whether any cleaning is required for the gridded sections
located behind and on the sides of the freezer due to the air flow
inadequacy.
If the power network warning light goes off and the freezer does
not operate;
• Check whether there is any power interruption,
• Check whether the power cord is plugged into the wall socket,
• Check whether the fuse in the house has blown,
• Check whether there is any rupture on the power cord.
• If the power network light is not lit but the freeze is operating;
the light needs to be changed. Ask for assistance from the authorised
service about the issue.
If the Chest Freezer is operating tumultuously;
• Check whether the freezer contacts with the walls or any other
furniture that can cause vibration.
• Ensure that the legs of the freezer are exactly stepping on the floor.
Содержание CF5500
Страница 1: ...COMMERCIAL CHEST FREEZER USER MANUAL Models CF5500 CF6600 CF6650 RFC469C RFC572C...
Страница 22: ...H10 20 320...
Страница 23: ...KOMER N TRUHLICOV MRAZNI KA U VATE SK PR RU KA Modely CF5500 CF6600 CF6650 RFC469C RFC572C...
Страница 44: ...H10 20 320 209...
Страница 45: ...KOMER N PULTOV MRAZNI KA U IVATELSK P RU KA Modely CF5500 CF6600 CF6650 RFC469C RFC572C...
Страница 66: ...H10 20 320...