Checkline TI-007 Скачать руководство пользователя страница 3

– 3 –

2 .0

OPERAT I ON

The TI-007 interacts with the operator through the membrane
keypad and the LCD display. The functions of the various keys
on the keypad are detailed below, followed by an explanation of
the display and its various symbols.

The Keypad

This key is used to turn the TI-007 on and off. When theTI-007 is turned 
ON
, it will first perform a brief display test by illuminating all of the segments
in the display. After one second, the tool will display the internal software 

version number. After displaying the version number, the display will show “0.0000” 
(or “0.000” if using metric units), indicating the tool is ready for use.

The TI-007 is turned OFF by pressing the ON/OFF key. The tool has a special memory
that retains all of its settings even when the power is off. The tool also features an auto-
powerdown mode designed to conserve battery life. If the tool is idle for 5 minutes, it will
turn itself off.

The CAL key is used to enter and exit the TI-007’s calibration mode. This 
mode is used to adjust the sound-velocity value that the TI-007 will use when 
calculating thickness. The tool will either calculate the sound-velocity from a 

sample of the material being measured, or allow a known velocity value to be entered
directly. Refer to page 7 for an explanation of the two CAL functions available.

The IN/MM key is used to switch back and forth between English and metric
units. This key may be used at any time, whether the tool is displaying a 
thickness (IN or MM) or a velocity value (IN/µs or M/s).

The UP arrow key has two functions. When the TI-007 is in calibration mode,
this key is used to increase numeric values on the display. An auto-repeat 
function is built in, so that when the key is held down, numeric values will

increment at an increasing rate. When the TI-007 is in measurement mode, this key is 
used to select between three different modes of measurement ( echo-echo, interface-echo,
or auto ). Refer to page 6 for an explanation of the calibration procedure and to review the
various measurement modes.

The SCAN key switches the SCAN measurement mode on and off. Refer to
page 8 for an explanation of the SCAN measurement mode.

The DOWN arrow key has two functions. When the TI-007 is in the CAL
mode, this key is used to decrease numeric values on the display. An auto-repeat
function is built in, so that when the key is held down, numeric values will

decrement at an increasing rate. When the TI-007 is not in calibration mode, the DOWN
arrow key switches the display backlight between three available settings. OFF will be dis-
played when the backlight is switched off. AUTO will be displayed when the backlight is
set to automatic mode, and ON will be displayed when the backlight is set to stay on. In
the AUTO setting, the backlight will illuminate while the TI-007 is making a measurement
and turn off after several seconds to conserve battery life.

– 14 –

8 .0

WARRAN T Y

ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original pur-
chaser that this product is of merchantable quality and confirms in kind and quality with
the descriptions and specifications thereof. Product failure or malfunction arising out of
any defect in workmanship or material in the product existing at the time of delivery there-
of which manifests itself within one year from the sale of such product, shall be remedied
by repair or replacement of such product, at ELECTROMATIC’s option, except where
unauthorized repair, disassembly, tampering, abuse or misapplications has taken place, as
determined by ELECTROMATIC. All returns for warranty or non-warranty repairs and/or
replacement must be authorized by ELECTROMATIC, in advance, with 
all repacking and shipping expenses to the address below to be borne by the purchaser.

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY
OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR
APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE
FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING
FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE
OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR
REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFAC-
TURER’S OR SUPPLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE
DATE.

Some State jurisdictions or States do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitation may not apply to you. The duration of any
implied warranty, including, without limitation, fitness for any particular purpose and 
merchantability with respect to this product, is limited to the duration of the foregoing
warranty. Some states do not allow limitations on how long an implied warranty lasts 
but, not withstanding, this warranty, in the absence of such limitations, shall extend for
one year from the date of invoice.

ELECTROMACTIC Equipment Co., Inc.

600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399

SCAN

CAL

ON

OFF

IN

MM

SCAN

SEND

DIFF

CAL

IN

MM

ON

OFF

ALRM

Содержание TI-007

Страница 1: ...ion and Preparation of Surfaces 2 6 Selecting Measurement Mode 2 7 Calibration 3 0 TI 007 Modes 8 3 1 Scan Mode 3 2 Alarm Mode 3 3 Diff Mode 3 4 S 232 Port 4 0 Transducer Selection 10 5 0 Appendix A Product Specification 11 6 0 Appendix B Application Notes 12 7 0 Appendix C Sound Velocities of Common Materials 13 8 0 Warranty Information 14 OI UT003 ...

Страница 2: ...ed in three sections The first section covers operation of the TI 007 and explains the keypad controls and display The second section provides guidelines in selecting a transducer for a specific application The last section provides application notes and a table of sound velocity values for various materials Electromatic maintains a customer support resource in order to assist users with questions...

Страница 3: ... TI 007 is not in calibration mode the DOWN arrow key switches the display backlight between three available settings OFF will be dis played when the backlight is switched off AUTO will be displayed when the backlight is set to automatic mode and ON will be displayed when the backlight is set to stay on In the AUTO setting the backlight will illuminate while the TI 007 is making a measurement and ...

Страница 4: ...al storage device via the TI 007 s RS232 port Refer to page 9 for an explanation of how to use this feature The Display The numeric portion of the display consists of four complete digits preceded by a leading 1 and is used to display numeric values as well as occasional simple words to indicate the status of various settings When the TI 007 is displaying thickness measurements the display will ho...

Страница 5: ...cer is the business end of the TI 007 It transmits and receives ultrasonic sound waves that the TI 007 uses to calculate the thickness of thematerial being measured The transducer connects to the TI 007 via the attached cable and one coaxial connector The transducer must be used correctly in order for the TI 007 to produce accurate reliable measurements Below is a short description of the transduc...

Страница 6: ...l inhibit proper transducer coupling Extremely rough surfaces such as the pebble like finish of some cast iron will prove most difficult to measure These kinds of surfaces act on the sound beam like frosted glass on light the beam becomes diffused and scattered in all directions In addition to posing obstacles to measurement rough surfaces contribute to excessive transducer wear particularly where...

Страница 7: ...s characteristics It may be necessary to experiment with a variety of transducers in order to find one that works well for a given job ELECTROMATIC can provide assistance in choosing a transducer and offers a broad selection of transducers for evaluation in specialized applications 7 large ranges The TI 007 provides two simple methods for setting the sound velocity described in the following pages...

Страница 8: ... 4 Assuming ALAr value flashing IN is displayed use the UP and DOWN arrow keys to scroll to the desired Lo alarm value 5 Press the SEND key to select the Lo value entered The Hi value will now be displayed Repeat step 4 select the Hi alarm value 6 The TI 007 is now ready to perform measurements using the Alarm feature Differential Mode In the Quality Control environment it is sometimes necessary t...

Страница 9: ...C E Q U I P M E N T C O I N 600 Oakland Ave Cedarhurst NY 11516 U S A TEL 516 295 4300 FAX 516 295 4399 CHECK LINE INSTRUMENTS CHECK LINE BY ELECTROMATIC MODEL TI 007 ULTRASONIC M ICROM ETER OPERATING INSTRUCTIONS ...