background image

 

CHCNAV ALPHAUNI 900 USER MANUAL

 

| 2020-06

 

P a g e  |  51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHC Navigation

 

Building D, NO. 599 Gaojing Road,

 

Qingpu District, 201702 Shanghai, China

 

 

Tel: +86 21 542 60

 

273 | Fax: +86 21 649 50 963

 

Email: [email protected] | [email protected]

 

Skype: chcnav_support

 

Website: www.chcnav.com

 

Содержание AlphaUni 900

Страница 1: ...Make your work more efficient CHCNAV AlphaUni 900 User Manual Mobile Mapping June 2020...

Страница 2: ...r 11 3 3 Product Details 11 3 3 1 AlphaUni 900 Hardware 11 3 3 2 Physical Characteristics 12 3 3 3 Electrical Characteristics 12 3 4 Primary Sensor Introduction 13 3 4 1 VUX 1UAV Laser Scanner 13 3 4...

Страница 3: ...Cable Connection 35 5 4 LiDAR Power On 35 6 Capture Operation Instructions 36 6 1 Remote Controller Unit 36 6 1 1 Controller Interfaces 36 6 1 2 Initialization Interface Description 37 6 1 3 Main Dis...

Страница 4: ...NAV provides below documents for user AlphaUni 900 multiplatform LiDAR user manual It is recommended for user to read above documents before first time using 1 4 Service Support CHCNAV website www chc...

Страница 5: ...r the relevant responsibility During equipment using time if customer disassembles and assembles the equipment without CHCNAV s suggestions permission and resulting in damage CHCNAV will not bear the...

Страница 6: ...lease use the cleaning kit to clean it Check whether the ports are clean and whether the pins are normal Check whether the connecting cables are reliable and stable and whether the GPS cable is stable...

Страница 7: ...whether the controller s laser parameter settings are correct If not correct please reset it again according to the project requirements 2 4 Tips After Using After using unplug the cable first then p...

Страница 8: ...high precision laser scanner and one inertial navigation system Due to its small structure and light weight it is suitable for data collection on various mobile platforms As an advanced mobile measure...

Страница 9: ...1 9 Softdog 1 10 Clean suits 1 11 Transport container 1 12 Standard Capture processing Software CoCapture 1 13 CoPre 1 14 Airborne Standard Configuration XT60 airborne power line 1 15 Airborne antenna...

Страница 10: ...hicle extension platform Roof rack extension 1 31 Other Professional backpack Backpack frame pro 1 32 Multiplatform backpack Lidar backpack 1 33 22000mAh smart battery 2 34 PC520 charger 1 35 PC1080C...

Страница 11: ...3 3 1 AlphaUni 900 Hardware ON OFF Power on or power off the instrument with green light ODO Wheel encoder interface FAN Fan connect interface DC24V Power interface with DC24V CAMERA External camera...

Страница 12: ...size 31 66 20 9 15 6 cm Instrument weight 4 5 kg Roof rack extension size 72 31 12 cm Roof rack extension weight 16 6 kg 3 3 3 Electrical Characteristics Input voltage DC24V 11 32 V Rated power 75 W...

Страница 13: ...or Introduction 3 4 1 VUX 1UAV Laser Scanner 3 4 2 High precision IMU The standard update rate is 200Hz but the option is up to 600Hz Orientation accuracy 0 01 Attitude accuracy 0 005 Positioning accu...

Страница 14: ...allation steps Push the slider of scanner into the quick release clamp which on the bottom of the airborne load plate in the direction of the arrow until hear a fix sound Tighten the side screw bolts...

Страница 15: ...of the quick release slider which locate at the bottom of the scanner to the direction of scanner head Tighten the bolt on the side handle of the antenna fixing fixture to complete the scanner and ant...

Страница 16: ...facture standard M8 screws to fix roof rack and vehicle cross bar THULE brand is recommended Then unscrew the screws of roof rack and adjust the extension length The maximum length is 400mm which divi...

Страница 17: ...CHCNAV ALPHAUNI 900 USER MANUAL 2020 06 P a g e 17...

Страница 18: ...maintain Push the scanner diagonally upward toward the scanner head to complete the separation The antenna removal method is the same as above 3 5 3 Vehicle Platform with Ladybug5 As shown in the figu...

Страница 19: ...l steps Install the top slider of the scanner to the V shaped chute of the backpack rod Tighten the handle bolts on the side of the scanner to complete the installation 3 5 4 2 Backpack disassemble st...

Страница 20: ...d cell and lithium battery Cable less connection between orange container and controller unit Support plenty functions such as low voltage alarm anti reverse connection and overcurrent protection The...

Страница 21: ...tainer consists of five parts output port display screen switch button input port and fuse Number 1 2 3 4 5 Name Output port Display screen Switch button Input port Fuse 1 Top View 2 Front View The de...

Страница 22: ...485A RS485B 4 1 3 Controller Box Port The top of controller box consists of seven parts self locking switch display screen input port 1 input port 2 24V output port 12V output port and fuse Number Nam...

Страница 23: ...ntainer is not used for a long time it is recommended to turn off it manually Otherwise it will turn off automatically after half hour under light condition 4 2 1 2 Orange Container Discharge Conditio...

Страница 24: ...und after alarm 4 2 1 6 Orange Container Overcurrent Protection The orange container supports overcurrent protection function If output port is short connection or current is higher than 30A the fuse...

Страница 25: ...V Output voltage 24V 10 2V 12 9V Output voltage stability 1 Output voltage adjusting range 10 4 2 2 2 Controller Box Working Condition The controller box supports both two output routes and two input...

Страница 26: ...phaUni 900 under operating state for display 4 2 2 5 Controller Box Overcurrent Protection The controller box supports overcurrent protection function If output port is short or current exceed than 30...

Страница 27: ...l height is 179mm and total weight is 8 1kg Same specification 12V lead acid or 12V lithium battery can also be used 4 3 2 Charger Parameters Different colors of charger light represent different use...

Страница 28: ...peration Instruction 4 4 1 Battery Installation Steps Prepared accessories list orange container standard battery 12 M3 6 torque 15Ncm and 4 M4 6 torque 50Ncm Clamp the electrode wire with the battery...

Страница 29: ...e 29 Put the cushion on the battery above for protection and prepared limiting plate and four screws for next step installation Install limiting plate on the above of cushion with four M4 screws Prep...

Страница 30: ...CHCNAV ALPHAUNI 900 USER MANUAL 2020 06 P a g e 30 Connect two power interfaces which shown in below Put the lower edge of cover completely inside the battery case and use 12 M3 screws to fix it...

Страница 31: ...06 P a g e 31 Finally complete orange container installation 4 4 2 Containers Assemble Steps First connect orange container and controller box which shown below Second tighten the screws if transport...

Страница 32: ...view Fourth press self locking switch of controller box to start 24V power supply 12V port is always powered Top view Can add more orange containers according to actual needs Two orange containers One...

Страница 33: ...0VAC and 110 130VAC Second step is to connect charger and orange container Open charger switch the charger light should present red and fan is start work which means in charge already Third step Batte...

Страница 34: ...her select suitable voltage range 115V or 230V Check whether the input or output fuses are burn out Check whether the orange container s fuse is burn out Battery cannot full charge Solution Keeping ch...

Страница 35: ...and equipment status are normal Detailed settings introduction please check Quick Guide 5 3 Cable Connection For vehicle platform if a wheel encoder is used connect the cable into ODO port Connect th...

Страница 36: ...Remote Controller Unit 6 1 1 Controller Interfaces The remote controller interface is mainly composed of four parts initialization interface main display interface system settings interface and laser...

Страница 37: ...rey which indicate abnormal communication and LiDAR is not connected If any one or more of the GNSS IMU and SD fail to pass the initialization the controller will stay in the initialization interface...

Страница 38: ...attery power When system timing fails the UNLOCK will be displayed When system timing is successfully the current UTC time is displayed User needs to check whether the current time is completely corre...

Страница 39: ...tion mode that control the camera to take photos which including time trigger distance trigger and manual trigger Data format TRIG0 Ladybug camera selecting TRIG0 TRIG1 Single camera selecting TRIG1 T...

Страница 40: ...synchronization state When the equipment is successfully timed it will display synchronized Otherwise it will display not synchronized Free memory It indicates the remaining capacity of the SD card Be...

Страница 41: ...mera selecting TRIG0 TRIG1 Single camera selecting TRIG1 TRIG2 Dual camera selecting TRIG2 Time intervals The time range is between 100 25500ms and the user should set the corresponding time interval...

Страница 42: ...rtant to note that the starting angle need to lower than the ending angle 6 1 4 3 Other settings Generally no use Usr cmd Support input relative code to check system when has issues Advanced settings...

Страница 43: ...s initialized successfully 4 After 5 minutes static alignment click Capturing to start laser data collection 5 When data collection is completed click Stop to stop laser data collection Then wait for...

Страница 44: ...A interface and PC and the other end of the network cable to computer network port Power on the equipment configure the network to 192 168 0 x X can be any number other than 128 after the laser initia...

Страница 45: ...storage path folder Tips Make sure the IP address is configured correctly otherwise the DataCopyTool software cannot be opened Select project first then choose Copy otherwise it will report an error...

Страница 46: ...and also can not delete internal folder 6 2 3 Data Structure BASE Save base data which recorded by GNSS receiver in static mode CCD Store pictures raw data LAS Store raw data of laser scanner PARA St...

Страница 47: ...ff Before turning off equipment please make sure the project is already stopped Long press equipment ON OFF button to turn off equipment until the light is out and buzzer is ring After the buzzer is s...

Страница 48: ...the equipment powered on As USB cable will power the camera in reverse which will cause the camera can not turn on Camera missed shooting There are two reasons may influence First is camera already sh...

Страница 49: ...r It is forbidden to plug and unplug each connection without cutting off the power supply Do not continue using any broken cables Please purchase and replace new cables in time to avoid unnecessary da...

Страница 50: ...otected with a dustproof cover If the equipment is disassembled or loosen it should be re calibrated When it is difficult to rotate any rotating parts of the equipment please do not forcibly rotate Af...

Страница 51: ...2020 06 P a g e 51 CHC Navigation Building D NO 599 Gaojing Road Qingpu District 201702 Shanghai China Tel 86 21 542 60 273 Fax 86 21 649 50 963 Email sales chcnav com support chcnav com Skype chcnav...

Страница 52: ...asures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver...

Отзывы: