6.1.6
Capture Process
1.
After the system is initialized successfully, click “
setting
” to config relative parameters as
required.
2.
After settings are saved, click “Create Prj” to start POS collection.
3.
When the time is starting, keep the equipment as stationary for more than 5 minutes to
ensure the IMU is initialized successfully.
4.
After 5 minutes static alignment, click “Capturing” to start laser data collection.
5.
When data collection is completed, click “Stop” to stop laser data collection. Then, wait
for 5 minutes and also keep static.
6.
Finally, click “Close Prj” to finish this project and power off the equipment later.
6.2
Data Copy
6.2.1
Manual Copy
6.2.1.1
Export POS data
Before the equipment is powered on, connect the data copy line between DATA interface and
PC first and then power on unit. PC will show an AlphaUni 900 disk where can copy POS data.